To insert power wire and connect the 9 to 48 V DC at a
maximum of 0.5 A DC power to the power terminal block, follow
the steps below:
• Use flat-head screw driver to loosen the wire-clamp screws
• Insert the negative/positive DC wires into the ( - /+) terminals,
respectively
• Tighten the wire-clamp screws to prevent the wires from loosen-
ing
!
ATTENTION:
Please use a power supply from 9 to 48 V DC, the
device power shall be supplied by SELV circuit.
!
ATTENTION:
This device complies with Part 15 of the FCC rules.
Operation is subject to the following conditions:
1. This device may not cause harmful interference
2. This device must accept any interference received
including interference that may cause undesired
operation
!
ATTENTION:
If the equipment is used in a manner not specified by
SALZ Automation, the protection provided by the
equipment may be impaired.
Connect one end of an Ethernet/RJ45 cable into Ethernet port
of SWITCH 2005GT and other end to attached networking
device.
• Ports 1-5 of the switch support Gbit Ethernet
(10/100/1000Base-T RJ45 Ports)
• All the RJ45 ports on the SWITCH 2005GT support auto
negotiation and auto MDI/MDI-X to eliminate the need for
crossover cabling
5.1.2 Cabling RJ45
Operating Temperature
-40˚C ... 70˚C
Storage Temperature
-40˚C ... 85˚C
Altitude
Up to 2000m
Ambient relative humidity
5 to 95% (non-condensing)
7. Environmental limits
6. LED Indicators
PWR
(Green)
Power On by terminal block PWR
Terminal block PWR fails or is not available
1000
(Green)
Link speed at 1000 Mbps
Data is transmitting / receiving
Link speed at 10/100 Mbps or no link
Copper port link-up
Data is transmitting / receiving
No link or link failed
Illuminated
Illuminated
10/100
(Green)
Off
Blinking
Off
Illuminated
Blinking
Off
Address of the manufacturer:
SALZ Automation GmbH
32105 Bad Salzuflen, Germany
Email: [email protected]
Please scan for more information:
v0.2
Note: Category 5e cable or above should be used.