6.3
Clean stainless steel surfaces
.
After using pungent cleaning agents, wash off the cleaned part thoroughly using water and rub
dry.
.
Clean stainless steel surfaces with grease-dissolving cleaner or a special stainless steel cleaner.
.
Dry cleaned parts and surfaces with a soft cloth.
7.
Faults and fault rectification
Check any faults in the appliance against the following table:
Fault
Possible cause
Action
The green indi
cator light does
not illuminate
when switched
on.
Main switch before appliance
not turned on.
Turn on main switch.
There is no power supply at
all.
Inform the power supply company.
Mains fuse on site has
tripped.
Possible faults on the appliance must
be checked by an authorised Customer
Service agent.
Reset the circuit breaker.
The appliance is
switched on but
does not heat
up.
The appliance is overheated.
Allow the appliance to cool.
If the fault continues to occur, contact
the authorised Customer Service.
If you cannot remedy the fault,
‒ switch off the appliance and disconnect from the mains,
‒ do not open the housing,
‒ contact the authorised Customer Service agent.