Conversion to a Different Gas Type
Observe the safety instructions, refer to page 18, chapter 1.
D
For conversion to different gas types, use original nozzles only.
.
After conversion to a different gas type and maintenance works:
−
Check all gas-bearing components for leak tightness (leakage spray),
−
attach a label stating gas type and gas pressure (mbar) to the gas range.
.
Read off the data required for conversion from the nozzle table/overview, refer to page 25,
chapter 7.1
7.1
Nozzle table / overview
Nozzle type
Gas type
Outer nozzle
Reduction nozzle
Pilot burner nozzle
Refer to page27, chap
ter7.2
Refer to page27, chap
ter7.3
For pilot burner nozzle
replacement, refer to
page28, chapter7.4
DE –
II
2ELL 3B/P
Natural gasE
Primary pressure
20 mbar
(DE)
ø1,85 mm
ø 1,05 mm
Two bores of
ø0.25 mm each
Natural gasLL
Primary pressure
20 mbar
(DE)
ø2,00 mm
ø1,05 mm
Two bores of
ø0.25 mm each
Liquid gas B/P
Primary pressure
50 mbar
(DE)
ø1,12 mm
ø0,60 mm
ø0,20 mm
GB –
II
2H 3+
Natural gasH
Primary pressure
20 mbar
(GB)
ø1,85 mm
ø 1,05 mm
Two bores of
ø0.25 mm each
Liquid gas 3+
Primary pressure
29/37 mbar
(GB)
ø1,3 mm
ø0,65 mm
ø0,20 mm
FR –
II
2E+ 3B/P
Natural gasE+
Primary pressure
20/25 mbar
(FR)
ø1,85 mm
ø 1,05 mm
Two bores of
ø0.25 mm each
Liquid gas B/P
Primary pressure
50 mbar
(FR)
ø1,12 mm
ø0,60 mm
ø0,20 mm