Version 1.0 08/2008
Page 5
Cooking manual Evolino II
Area of application for Multifunction touch key
Choosing other
features
Switch on the combi-steamer
Press the
and
at the same time.
A
n acoustic signal will sound and the memory opens.
With the turning knob “time” the following features can be
programmed:
-
Regenerating “rE”
-
Low temperature cooking “lt”
-
Delta T “dT”
Hold the Multifunction touch key to save the settings- a signal
will sound!
By starting the combi-steamer and choosing the Multifunction
touch key the programmed feature will appear by indicating the
temperature. Core temperature and time need to be adjusted
every time.
Multifunction key
assigned for
“Banquet /
Regeneration
rE" for Banquet / Regeneration
Press key. LED lights up. The temperature display shows
140°C (automatic default setting).
Temperature range: 90 to 180°C.
Additional functions: Steaming and humidifying.
Multifunction key
assigned for
“Lt Cooking”
"Lt" for Low temperature cooking
Press key. LED lights up.
The temperature display shows 80°C (automatic default
setting).Temperature range: 30 to 120°C.
Additional functions: Steaming and humidifying
Multifunction key
assigned for
“DeltaT Cooking
dt" for DeltaT Cooking
Press key. LED lights up. The temperature display shows 40°C
(automatic default setting). Adjust the delta between 30 and 40
to receive a perfect result
Entry field: The time diplay is enabled while working with core
temperature; adjust core temperature between to 99°C.
Additional functions: Steaming and humidifying.