4
Electrical
GENERAL INSTRUCTIONS
Dual voltage disposers are shipped from the factory
NOT connected for a specific voltage. Please refer to the
wiring diagrams on the disposer junction box cover. When
connecting single phase disposers to a reversing control,
refer to the diagram supplied with the control. Salvajor
disposer cutting elements are designed to operate in
either direction.
Use water tight conduit and fittings to make connections.
Caution: Be careful not to pinch wires when replacing
junction box cover.
For new installations, an approved control will need to be
mounted on or near the dish table with an optional bracket.
Power will have to be run to a solenoid for incoming water.
NOTE:
The RESET button is located on the bottom of the dis-
poser.
TEST PROCEDURE
1.
Check to be sure the disposer cutting teeth are free of
foreign objects.
2.
Turn the disposer on and determine that the cutting
elements rotate freely and that water flows automatically.
3.
Check the mounting assembly and plumbing connections
for leaks.
4.
If disposer fails to operate:
A.
Turn off power.
B.
Check wiring connections.
C.
Determine if the RESET button has tripped.
Reset by hand only.
DANGER:
If disposer stops, DO NOT look for the cause until the
starting control is turned OFF and the power is turned OFF.
Consult Operating Instructions.
Model 100
115 Volts
1 Phase
18.6 Amps
208 Volts
1 Phase
10.2 Amps
230 Volts
1 Phase
9.3 Amps
208 Volts
3 Phase
4.9 Amps
230 Volts
3 Phase
4.5 Amps
460 Volts
3 Phase
2.3 Amps
Model 100
(1 HP)
Model 200
115 Volts
1 Phase
24.0 Amps
208 Volts
1 Phase
12.1 Amps
230 Volts
1 Phase
12.0 Amps
208 Volts
3 Phase
6.6 Amps
230 Volts
3 Phase
6.0 Amps
460 Volts
3 Phase
3.0 Amps
Model 200
(2 HP)
Model 300
208 Volts
3 Phase
8.8 Amps
230 Volts
3 Phase
8.0 Amps
460 Volts
3 Phase
4.0 Amps
Model 300
(3 HP)
Model 500
208 Volts
3 Phase
13.8 Amps
230 Volts
3 Phase
12.5 Amps
460 Volts
3 Phase
6.3 Amps
Model 500
(5 HP)
Full Load Amps
MAKE ALL INSTALLATIONS IN ACCORDANCE
WITH LOCAL AND NATIONAL ELECTRICAL CODES.
WIRING DIAGRAMS
5
L 2
L 1
J
2
1
4
8
3
SINGLE PHASE 115 VOLT
5
J
2
8
3
1
4
L 2
L 1
SINGLE PHASE 208 VOLT
5
J
2
8
3
1
4
L 2
L 1
SINGLE PHASE 230 VOLT
L 2 L 3
L 1
2
3
1
8
9
7
5
6
4
11
12
10
3 PHASE 208/230 VOLT
TO REVERSE ROTATION: Interchange #5 & #8 (Single Phase Only)
USE CONTROL PANEL WIRING DIAGRAM when using Salvajor Controls
(Models ARSS, ARSS-LD, ARSS-2 or MRSS) (Single Phase Only)
L 2 L 3
L 1
2
3
1
8
9
7
5
6
4
11
12
10
3 PHASE 460 VOLT