![Salus SC428ZW Скачать руководство пользователя страница 2](http://html1.mh-extra.com/html/salus/sc428zw/sc428zw_installation-and-user-manual_3621465002.webp)
Events
Association Group
Using association group, the Smart Plug is able to command or notify another device
of a Z-Wave® network.
Group
Group Name
1
Lifeline
2
Follow State
3
Follow Complementary State
4
Metering - High Threshold-Set On/Off
5
Metering - Low Threshold-Set On/Off
SMC-QG-SC428ZW-202101v1
Z-Wave User Configuration
Parameter
Description
Values
Size
Byte)
Default
1
Status when
powered up
0 = Off
1 = On
2 = Status when last powered
1
2
3
Enable/
Disable for
Group 2 & 3
0 = Group 2 & 3 disabled
1 = Group 2 enabled
2 = Group 3 enabled
3 = Group 2 & 3 enabled
1
3
5
Overvoltage
Alarm (V)
1-200 = Overvoltage Alarm threshold
2
132
6
Overcurrent
Alarm (mA)
1-15000 = Overcurrent Alarm threshold
2
15000
21
Power
Change
Report
1 - 100 = % Power Change to Send Report
1
10
22
Overload
Power Re-
port
1 – 1980 = 1 to 1980W
2
1980
23
Energy
Report
1 – 327 = 1 KWh to 327 KWh
2
1
24
Metering
Report
30 – 32767 = 30 – 32767 seconds to send report
2
3600
25
High Power
Threshold
0 = High Power Threshold disabled
1 – 32767 = High Power Threshold (Watts)
2
1980
26
Low Power
Threshold
0 = Low Power Threshold disabled
1 – 32767 = High Power Threshold (Watts)
2
5
27
Power
Threshold
Action
1 = Power Threshold Action disabled
2 = Power High Threshold is enabled and send OFF
to group 4
4 = Power High Threshold is enabled and send ON
to group 4
8 = Power Low Threshold is enabled and send OFF
to group 5
16 = Power Low Threshold is enabled and send ON
to group 5
12 = 4 AND 8
1
12
User Event
Notification Type
Notification Event
Overvoltage
threshold is met
Power Management
(0x08)
Overvoltage Detected
(0x07)
Overcurrent
threshold is met
Power Management
(0x08)
Overcurrent Detected
(0x06)
Overload
threshold is met
Power Management
(0x08)
Overload Detected
(0x08)
Group 1 - Lifeline
Maximum number of devices in group: 5
This group is generally used to report information of the Smart Plug to the Main
Controller of the network, including Meter, Binary Switch Report, Notification and
Device Reset Locally.
Group 2 - Follow State
Maximum number of devices in group: 5
When the Smart Plug is switched ON (respectively OFF) using the local button,
it will send ON (respectively OFF) command to the associated devices. No
command is sent if the Smart Plug is switched ON or OFF wirelessly. This group is
configurable through the parameter 3.
Group 3 - Follow Complementary State
Maximum number of devices in group: 5
When the Smart Plug is switched ON (respectively OFF) using the local button,
it will send OFF (respectively ON) command to the associated devices. No
command is sent if the Smart Plug is switched ON or OFF wirelessly. This group is
configurable through the parameter 3.
Group 4 - Metering - High Threshold - Set On/Off
Maximum number of devices in group: 5
When the Smart Plug reaches over the high threshold of power defined by the
configuration parameter, it will send OFF or ON command to the associated
devices. This group is configurable through the parameters
25 and 27.
Group 5 - Metering - Low Threshold - Set On/Off
Maximum number of devices in group: 5
When the Smart Plug reaches below the low threshold of power defined by
the configuration parameter, it will send OFF or ON command to the associated
devices. This group is configurable through the parameters
26 and 27.
Z-Wave Related Configuration
Specific Configuration Role Type:
Role Type:
• Always On Slave (AOS)
• Device Type: BINARY_SWITCH
• Supported security keys: S2
• Unauthenticated
Library:
• Generic Type: SWITCH_BINARY
• Specific Type: POWER_SWITCH_BINARY
Z-Wave Command Class Support
ZWAVEPLUS_INFO V2
CONFIGURATION V1
TRANSPORT_ SERVICE V2
BASIC V2 (Control and Support)
MANUFACTURER_SPECIFIC V2 VERSION V3 - ASSOCIATION V2
DEVICE_RESET_LOCALLY V1
ASSOCIATION_GRP_INFO V3
SECURITY_2 V1
SUPERVISION V1
POWERLEVEL v1
FIRMWARE_UPDATE_META_DATA V4
BINARY_SWITCH V1
PROTECTION V2
METER V4
MULTI_CHANNEL_ASSOCIATION V3
Notification V8