Before connecting the relay module with a different device make sure that its parame-
ters are consistent with the RM-16A module specification. Incorrect connection may
cause undesirable action, excessive overheating and combustion hazard. To avert the
hazard make sure that the relay module RM-16A is correctly connected. The connection
of the device can be done only by a qualified installer who has up-to-date eligibility.
SL
N
L
NO
COM
NO
COM
VOLTAGE
FREE
INPUT
NC
μ 16
A
/
250
V
AC
4000 VA
RM-16A
INPUT
230
V
AC
POWER SUPPLY
230
V
AC / 50 Hz
SAFETY INFORMATION
VISUAL ASPECT
Power:
16A / 250V AC, 4000VA
INPUT NO/COM:
Connection of a regulator with the free
voltage relay NO/COM
OUTPUT NC/COM/NO:
Output receiver
INPUT SL:
Connection of the regulator with the
voltage relay 230V
POWER SUPPLY N/L:
Power of 230V AC/50Hz
Measurements:
47x47x21
relay output (NO, COM, NC)
INTRODUCTION
Relay module RM-16A opens and closes the circuit in order to affect the work of other
devices. Some uses of the module RM-16A with other Salus products are shown below:
1. Connection of the thermostat with the voltage relay 230V (e.g. VS30/RT200/ERT20/
ERT30/ERT50/VS10) with a gas-fired boiler which requires free-voltage output NO/COM
or NC/COM
2. Connection of the SALUS thermostat with the NO/COM relay (e.g. 091FL) with the
boiler control which needs NC/COM output (NC/COM output is normally required in
the solid fuel boiler controls)
3. Connection of the receiver transmitting power higher than it is allowed by the relay
in a regulator. The maximum electricity consumption of the receiver cannot exeed 16A
4. Connection of the devices other than electro thermal actuators with the wiring
centre ( KL06-M/KL08NSB /KL08RF/KL10/KL10RF) e.g. if you want to connect a pump or
an electric heating mat instead of a electro thermal actuator.
PRODUCT SPECIFICATION
Power supply of the modul RM-16A-230V AC
Control input with the voltage output 230V
Control input with free-voltage output
LED signalling short circuitof the relay output