pairing  process.  Check  with  your  connected  home  system 
procedures for more details. 

 

Prepare connected home system to add a thermostat. 

 

Go to the

 PAIR 

menu item on the OPTIMA thermostat. 

 

Press  MODE  to  select  pairing  mode.  Display  will  show

'

WILL 

PAIR

 

Press MODE again to enter pairing mode. Display will show the 
number 10 and

 Pairing

 

Wait  for  the  connected  home  system  to  recognize  the 
thermostat. The thermostat will blink

 IDENTIFY 

and return to 

the Home Screen

 

when the thermostat has been added to the 

system. The blinking

 IDENTIFY 

will go away after 3 minutes. 

UPDATE 

This  menu  item  initiates  a  check  for  new  firmware  on  the 
connected home system and updates the firmware automatically if 
one is found. 

OPTIMA'ZigBee'Thermostat'

9

'

'

Remove'Old'Thermostat'

Remove  the  old  thermostat  from  the 
wall, taking care not to allow the wiring 
to fall inside the wall. 

Install'Mounting'Plate'

Remove the mounting plate from the back of the Optima thermostat. 
Use  the  included  wall  anchors  and  screws  to  attach  the  mounting 
plate  to  the  wall,  making  sure  the  wires  run  through  the  center 
opening. 
If there is space on the wall from 
the  old  thermostat  that  needs  to 
be  covered,  insert  the  trim  plate 
between  the  mounting  plate  and 
the  wall,  and  mount  both  plates 
using  the  same  anchors  and 
screws.  The  trim  plate  can  be 
oriented  vertically  or  horizontally 
for proper coverage. 

TIP:

' Wrap' the' wire' ends'

around'a'long'stick,'such'as'
a' pencil' to' keep' the' wires'
from'falling'into'the'wall.'

Содержание OPTIMA ZigBee

Страница 1: ...Version 1 0 Salus Controls Inc 123 Townsend St Level LL2 San Francisco CA 94107 For other language versions please visit www salusinc com OPTIMA ZigBee Thermostat User Manual...

Страница 2: ...limits set forth for an uncontrolled environment This equipment should be installed and operated with a minimum distance of 20 centimeters between the antenna and all persons Industry Canada Under Ind...

Страница 3: ...requency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur...

Страница 4: ...POWER TO HVAC SYSTEM 7 DETERMINE WIRING CONFIGURATION 7 REMOVE OLD THERMOSTAT 9 INSTALL MOUNTING PLATE 9 ATTACH WIRING 10 INSTALL BATTERIES 10 INITIAL CONFIGURATION 11 ATTACH THERMOSTAT TO MOUNTING P...

Страница 5: ...POINT TEMPERATURE 14 CHANGING THE OPERATING MODE 15 TURNING ON THE FAN 15 CONFIGURING THE THERMOSTAT 16 CONFIGURATION MENUS 16 RESET TO DEFAULTS 21 SPECIFICATIONS 22 TROUBLESHOOTING 23 SALUS WARRANTY...

Страница 6: ...SYSTEM 29 SINGLE TRANSFORMER HEAT PUMP SYSTEM 30 TWO TRANSFORMER HEAT PUMP SYSTEM 31 APPENDIX B REGULATORY STATEMENTS 32 FCC STATEMENTS 32 FCC AND INDUSTRY CANADA 33 INDUSTRY CANADA 33 OPTIMA ZigBee...

Страница 7: ...Conventional Two Transformer Heat and Cool System OPTIMA ZigBee Thermostat 1 IN THE BOX Thermostat with Mounting Plate Trim plate Screws and Anchors Wire Labels 2 x AA alkaline batteries User s Manua...

Страница 8: ...Salus User Manual CONTROLS AND DISPLAY Buttons Slider Ring Next Previous Fan Hold Back Mode Enter Reset on bottom of unit OPTIMA ZigBee Thermostat 27 Conventional Single Transformer Heat and Cool Syst...

Страница 9: ...increment or counter clockwise to decrement values Display next previous option Previous Tap to decrement values Display previous option Next Tap to Increment values Display next option FAN HOLD Back...

Страница 10: ...ement as provided herein If a Product under warranty is defective the Customer may contact the party Seller from which the Customer purchased the Product to obtain an equivalent replacement product af...

Страница 11: ...the Product Any implied warranties including warranties of merchantability or tness for a particular purpose are limited to the Warranty Period or the shortest period allowed by law SALUS SHALL NOT BE...

Страница 12: ...eck that the connector pins are straight Check that the thermostat is fully seated on the mounting plate If the terminal connections are not fully engaged the firmware does not activate the relays Thi...

Страница 13: ...Thermostat 7 Tools You may need the following tools to install the Optima thermostat Smartphone or camera to take pictures Phillips or flathead screwdriver Small screwdriver to disconnect wires from...

Страница 14: ...P NonHHP Wire Color R RC RH C C L Y1 Y1 Y2 Y2 W1 W1 O B W2 G G OPTIMA ZigBee Thermostat 21 Reset To Defaults The RESET button is located on the bottom surface of the OPTIMA and can only be accessed wi...

Страница 15: ...n the connected home system and updates the firmware automatically if one is found OPTIMA ZigBee Thermostat 9 Remove Old Thermostat Remove the old thermostat from the wall taking care not to allow the...

Страница 16: ...ee Thermostat 19 Offset should the temperature sensor need calibration This value is added to the sensed temperature to determine the room temperature Range 7 F in 1 degree increments 4 C in 0 5 degre...

Страница 17: ...nfiguration After inserting the batteries the display will flash all the segments followed by the firmware version number then display US CA with a blinking US When configuring the thermostat select t...

Страница 18: ...ostat The thermostat can now be used as a local manual thermostat but to enable the enhanced features additional settings need to be configured See the Configuring the Thermostat section for more deta...

Страница 19: ...to select another menu item at the same level To return to a higher level menu item at any time press the FAN HOLD button OPTIMA ZigBee Thermostat 13 USING THE THERMOSTAT The OPTIMA thermostat offers...

Страница 20: ...ired set point temperature and press the FAN HOLD button while the set point temperature is blinking The word HOLD will appear in the Label Area to indicate the HOLD state OPTIMA ZigBee Thermostat 15...