background image

           

 - antifrost mode 5°C

(changing temperature is avaible 

only through the app)

             

 - automatic mode  

(works according to the schedule)

Press               or                button  

to set start hour for program 1. 

Press             button to confirm.

Press               or                button  

to set start hour for program 1. 

Press             button to confirm.

Press               or                button  

to set start minutes for program 1. 

Press             button to confirm.

Press               or                button  

to set start minutes for program 1. 

Press             button to confirm.

You can cancel temporary override by holding               button  
for 3 seconds. Setting indicator               should disappear.

Press              or              button 

to change temperature.

Press             button to confirm.

Set hour value of boosting your 

hot water by pressing     

            or                button. 

Press             button to confirm.

Press          button to select 

temperature zone or HW.*

Press          button to select 

temperature zone or HW.*

Press          button to select 

temperature zone.*

Press          button to select  

hot water system          .

*(only in two heating zones or one heating 

zone + hot water system)

*(only in two heating zones or one heating 

zone + hot water system)

*(only in two heating zones)

When iT500RX receiver  

and iT500 thermostat are paired 

then the light will be green.

Press              or                 to return  

to the home screen.

iT500 has successfully paired with 

iT300 when the antenna stops 

flashing.

Press              or                 to return  

to the home screen.

    Press and hold          and          

                  buttons for 3 sec.

    Press and hold          and          

                  buttons for 3 sec.

    Press and hold          and          

                  buttons for 3 sec.

GMT

GMT+1 Hour

GMT+2 Hour

GMT+3 Hour

or

or

or

Press              or              button 

to select temperature unit. 

Press             button to confirm. 

Press                or               button  

to select operating mode. 

Press             button to confirm. 

Press              or              button  

to select time zone (GMT). 

Press             button to confirm. 

Press              or              button to select heating        or cooling*         mode. Press             button to confirm. 

*Cooling can only be selected if your system supports this.

5a

5b

6

7

5c

UK
IRELAND
PORTUGAL
ICELAND*

RUSSIA*

AUSTRIA
POLAND
GERMANY
CZECH
SPAIN
FRANCE
ITALY
SWITZERLAND
LUXEMBOURG
HOLLAND

BELGIUM
DENMARK
SWEDEN
NORWAY
MALTA
CROATIA
SERBIA
BOSNIA
SLOVENIA
SLOVAKIA

ESTONIA
TURKEY
CYPRUS
GREECE
ROMANIA
RUSSIA
UKRAINE

BULGARIA
LITHUANIA
BELARUS*
FINLAND
MOLDOVA
LATVIA

The countries marked with * do not observe Daylight Saving Time. For details please see below.

8

DST (Daylight Saving Time) ON will automatically change your time 

from summer to winter.

Press              or              button 

to turn ON or OFF day saving 

time function. 

Press             button to confirm. 

Pairing iT500 with iT500RX receiver

Program schedule for heating zone

Program schedule for hot water system

Setting the temperature

Operating modes

Setting the time and date

Pairing the iT300 to the thermostat

Lock Function

Using a paper clip, insert into the 

hole marked SYNC at the bottom 

of iT500RX receiver. 

To pair iT300 to the receiver, insert 

a paperclip or similar object into 

the hole on the left hand side  

of iT300 for 2 seconds.

Press             button to launch 

pairing process.

Press             button to launch 

pairing process.

Press               or                button  

to set temperature level for 

program 1. Press             button  

to confirm. Follow the steps 7-9 

to set next programs. 

Set time for turn OFF program 1

cognately to step 7-8. 

Press             button to confirm. 

Follow the steps 7-9 to set 

next programs. 

The bottom switch will show 

a constant red light when iT500RX 

receiver is ready to pair. 

Now go to iT500 thermostat.

A red light will flash in the top 

right hand corner of the iT300.

Pairing process can take 

up to 10 minutes.

Pairing process can take 

up to 10 minutes.

1

1

5

5

2

2

6

6

3

1

3

4

2

4

7

7

FAILSAFE MODE:

 In the event of RF signal loss, your system will  

be switched on for 4 minutes, then off for 11 minutes. If you want to 

disable FAILSAFE MODE when RF link has been lost then move the 

slide switch on iT500RX to either the Manual or Off position.

The iT300 should be installed 

in the area of the house that 

the second zone will be 

controlled from, ie. Upstairs.

Please note the red LED  

on the iT300 will continue to 

flash and eventually timeout.

You can easily set your schedule via iT500 Plus app          . If you want to set schedules directly by the iT500 

thermostat, please follow the instruction below.

When connected to the internet, the iT500 will set time and date automatically. However this can also be set 

manually.

1

4

2

5

3

6

Press and hold          button.

Press again          button  

to change value.

Press             button to confirm.

Press              or             button  

to set 12 or 24 hour format.

Press             button to confirm.

Press              or             button 

to set the hour.

Press             button to confirm.

Follow the same steps to set  

the minutes, day, month  

and year.

Permanent manual mode

To enable or disable lock function press and hold             and              buttons 

together.

         Press the power button       

to highlight the display.

         Press the power button       

to highlight the display.

         Press the power button       

to highlight the display.

1

2

3a

3b

         Press the power button       

to highlight the display.

Press and hold         button  

for 3 seconds.

Press and hold         button  

for 3 seconds.

Press             button to confirm.

Press             button to confirm.

Press             button to confirm.

Press             button to confirm.

1

1

4

4

7

7

2

3

2

5

5

8

8

3

4

3

6

6

9

9

         Press the power button       

to highlight the display.

         Press the power button       

to highlight the display.

Note:

 In program schedule for hot water system (HW)       you can set 3 schedule programs per day.  

For each HW program you must define the time of start and the time of the end. 

Note: 

When you set program schedule, necessarily set all 6 programs. I.e. if you want to set 2 

temperature levels, you need to set first temperature level for 1 to 5 program and set second 

temperature level only for program 6.

In iT500 thermostat you can define 6 schedule programs per day. You can set different temperature level for each 

program. While programming specific time interval you must be aware that you are about to set at what time the 

program will start. For example, if you set program 1 for 6:00 (AM) it means the program is going to run at 6:00 (AM) 

and will running till the time set for next program. Example of 4 temperature levels for 6 schedule programs:

P1

17°C

17°C

22°C

23°C

23°C

23°C

19°C

P2

P3

P4

P5

P6

P1

0           1            2           3           4           5           6            7           8           9         10           11        12         13        14           15         16         17         18        19         20         21         22        23        24

Press           button to choose  

ALL, 5/2 or INDIVIDUAL days.

Press             button to confirm.

Press           button to choose 

ALL, 5/2 or INDIVIDUAL days.  

Press             button to confirm.

Setting up the iT500 thermostat

After powering up iT500 for the first time the display will go through the following sequence.

OTA (Over The Air 

operated software) 

revision number

The globe icon               will 

appear when the unit 

automatically connects to 

the internet via the SALUS 

iTG500 Gateway. This 

should take approximately 

20 seconds.

iT500 Software revision

1

3

2

4

Selecting your system configuration

At any time press                for return to the previous step or hold                for 5 seconds to return to the home screen.

Press and hold     

        and               buttons for 3 sec.

Press             button to confirm.

Two central heating zones.

One central heating zone.

+

+

One central heating zone 

+ hot water system

Press             or              button to select your system configuration. To confirm press             button.

This menu should only be entered by the installer as changes can have a detrimental effect on your heating system.

1

2

4b

4a

3

4c

         Press the power button       

to highlight the display.

Note: 

If you set the temperature in AUTO mode (temporary override) the setpoint temperature won’t be 

changed until the next program starts.

Note: 

iT300 purchased separately. Can only be used if your system supports second central heating zone. 

Отзывы: