background image

INSTALLATION

Please read the important safety information at the start of this manual before you
begin to install the device.

The Frost Thermostat should be located in the coldest part of the building, but where
it can respond to a rise in temperature when the boiler switches on. The ideal position
to locate the FT100 frost thermostat is about 1.5m above floor level, in a location
where the thermostat is accessible, reasonably lit and free from extremes of
temperature and draughts. Do not mount the thermostat on an outside wall, above a
radiator or in a location where it may be subjected to direct sunlight.

The electrical connections to the FT100 are made to the supplied industry standard
backplate. This simplifies installation, as no connections are made to the controller
itself. Connection details are shown below - no Earth connection is required for the
correct and safe operation of the FT100, but a parking terminal is provided to connect
an Earth wire if one is present.

FT100 INSTRUCTION MANUAL

4

Backplate Connections

Terminal

Description

Backplate

N

Mains Neutral

L

Mains Live

SL

Switched Live 
(Normally Open Contact)

Earth Parking (no electrical 
connection)

After installing the backplate in a suitable location, wiring connections can be made 
as shown above. The following criteria apply to the installation:
• The incoming AC mains supply should be 230V AC and fused at 5 amps.
• Optimum cable size for installation is 1.5 mm2; wiring colours should be in 

accordance with the current requirements of the IEE Wiring Regulations.

• Cable entry should be from the rear of the backplate.
• All wiring connections should be securely made, and be firmly gripped 

beneath the square brass washer on each terminal.

Salus FT100 Manual 001:89  29/11/10  22:57  Page 4

Содержание FT100

Страница 1: ...Instruction Manual Model No FT100 Electronic Frost Thermostat 2 Salus FT100 Manual 001 89 29 11 10 22 57 Page 1...

Страница 2: ...ntended to apply in the United Kingdom only and should be followed along with any other statutory obligations This accessory must be fitted by a Competent person and installation must comply with the...

Страница 3: ...ols is a stylish mains voltage thermostat that can switch a pump zone valve or boiler to provide localised protection from freezing regardless of the heating controller settings Fitted with a protecti...

Страница 4: ...er itself Connection details are shown below no Earth connection is required for the correct and safe operation of the FT100 but a parking terminal is provided to connect an Earth wire if one is prese...

Страница 5: ...right to set a higher temperature Refit the protective cover after you have finished adjusting the set temperature The Light Emitting Diode LED on the front panel will light when the temperature is be...

Страница 6: ...ching Switching Voltage 230V AC 50Hz Switching Current 8A resistive 3A inductive Contact Type Single Pole Single Throw SPST Temperature Range 10 C to 20 C Accuracy 1 C at 25 C Environment Operating Te...

Страница 7: ...s from the date of purchase Salus Controls sole liability for breach of this warranty will be at its option to repair or replace the defective product FT100 Warranty Customer Name Customer Address Pos...

Страница 8: ...01226 323961 Email tech salus tech com Tel 01226 323961 Sales Technical Salus Controls plc Salus House Dodworth Business Park South Whinby Road Dodworth Barnsley S75 3SP salus tech Salus FT100 Manual...

Отзывы: