51
The splicer suddenly shut down
The splicer turned off automatically when the machine
is set for automatic machine shutdown (default 30
minutes) without any operations.
Fiber identification errors under
AUTO mode
AUTO mode only for standard SM, MM, NZ optical
fibers. When splice special fibers, AUTO mode may
not recognize correctly.
The estimated loss is different from
the real loss
1) The estimated loss is evaluated just for reference.
2) The optical components needed to be cleaned.
Heat shrinkable tube doesn’t shrink
completely
Extend the heating time.
How to cancel heating
If user want to terminate the heating, press HEAT
button, then the LED light will turn off.
The heat shrink tubing is stuck in
the heating tank after heating
Remove the heat shrink tubing with a thin cotton swab
or soft bar.
After discharge calibration, the
discharge intensity did not change
The discharge calibration changes the internal
condition parameters, not the discharging strength.
Содержание SFS-3000 Series
Страница 21: ...8 SFS3000 02 Hanging neck type working tray...
Страница 27: ...14 Charge the battery 4 4 Power on Press the power button and wait for it to enter into working platform...
Страница 28: ...15 In the initial interface press the to adjust the LCD brightness...
Страница 36: ...23...
Страница 47: ...34 Choose and edit the parameter after which press Confirm...