CARE AND CLEANING
1) Unplug from the wall outlet.
2) Clean the Induction Cooktop and the Control Panel with a damp cloth.
NOTE:
• Do not use a brush or abrasive cleansers. This may damage the Cooktop.
• Do not immerse the unit in water or any other liquid.
3) Dry with a soft cloth.
4) Clean the unit after each use.
TROUBLESHOOTTING:
5
Error Codes
Reason
Solution
E3, E6
Overheating or dry
• Ensure that the air inlet or
the exhaust outlet are not
blocked.
• Ensure that the fan is running
• Check to see if the pot has boiled
dry. If so, turn off the cooker and
let it cool down.
E7, E8
Voltage not suitable
• The voltage has either increased
over 140V or decreased below
90V
E1, E2, E4,
E5, Eb, EC
Internal parts are either
overheating, have an open
or short circuit
• Contact the service centre. See
last page of the instruction
booklet for contact information.
Booklet_ID-1172_ENG.qxd:Salton Booklet 7/15/09 10:28 AM Page 5