Salto UBOX 4000 Скачать руководство пользователя страница 3

All contents current at time of publication.
SALTO Systems S.L. reserves the right to change availability of any
item in this catalog, its design, construction, and/or materials.

©

2020 SALTO Systems S.L.

226079-ED2.- 12/02/2021

XS4 Controller

Installation guide

UBOX4000

Factory configuration

Configuración de fábrica

IN1
IN2
IN3
IN4
IN5
IN6
RL1
RL2
RL3
RL4

IN1

IN2

IN3

IN4

IN5

IN6

RL1

RL2

RL3

RL4

IN1
IN2
IN3
IN4
IN5
IN6
RL1
RL2
RL3
RL4

Input connections

Supervised input connections

CUADAP or third partie readers

IN3
IN4
IN5
IN6

D0 output
D1 output
D0 output
D1 output

Clock output

Data output

Clock output

Data output

TX output

TX output

Configuration d’usine

Wiegand

Omron

RS232

The resistance value R1 and R2 are defined in
the software: 1k (recommended), 1k5, 2k2,
3k3, 4k7 6k8, 10k

Conexión de las entradas

Conexión de las entradas supervisadas

CUADAP o lectores de terceros

IN3
IN4
IN5
IN6

Salida D0
Salida D1
Salida D0
Salida D1

Salida reloj

Salida Datos

Salida reloj

Salida Datos

Salida TX

Salida TX

Wiegand

Omron

RS232

El valor de resistencia R1 y R2 se define en el
Software: 1k (recomendado) ,1k5 ,2k2 ,3k3,
4k7, 6k8, 10k

Connexion d’entrée

Connexion d'entrée supervisée.

CUADAPT ou lecteur tiers.

IN3
IN4
IN5
IN6

Sortie D0
Sortie D1
Sortie D0
Sortie D1

Sortie Clock

Sortie Data

Sortie Clock

Sortie Data

Sortie TX

Sortie TX

Wiegand

Omron

RS232

La valeur des résistances R1 et R2 sont définies
dans le logiciel : 1k (recommandé), 1k5, 2k2,
3k3, 4k7, 6k8, 10k.

R2

R1

R1=R2

R2

R1

R1=R2

R2

R1

R1=R2

E

Eng

F

Eng

E

F

(Input supervision has not been evaluated by UL)

3/18

By default not configured
By default not configured
By default not configured
By default not configured
By default not configured
By default not configured
By default not configured
By default not configured
By default not configured
By default not configured

Por defecto no configurados
Por defecto no configurados
Por defecto no configurados
Por defecto no configurados
Por defecto no configurados
Por defecto no configurados
Por defecto no configurados
Por defecto no configurados
Por defecto no configurados
Por defecto no configurados

Par defaut non configuré
Par defaut non configuré
Par defaut non configuré
Par defaut non configuré
Par defaut non configuré
Par defaut non configuré
Par defaut non configuré
Par defaut non configuré
Par defaut non configuré
Par defaut non configuré

Содержание UBOX 4000

Страница 1: ...VDC Input A B 12VDC Output 1A Power Input 12V DC 1A GND GND A B Model CU42E0 104 4 1 8 121 4 3 4 43 1 11 16 10 3 8 44 1 3 4 131 5 3 16 4 5 32 UBOX42DxxG UBOX42DxxT Model CU42xx UBOX 4000 MODEL CU42E0...

Страница 2: ...e a la entrada de alimentaci n protegida por un fusible de 1 A BUS485 Entradas el instalador ha de identificar el cable para el puente dependiendo de la configuraci n de la entrada Conexi n para el PP...

Страница 3: ...el Software 1k recomendado 1k5 2k2 3k3 4k7 6k8 10k Connexion d entr e Connexion d entr e supervis e CUADAPT ou lecteur tiers IN3 IN4 IN5 IN6 Sortie D0 Sortie D1 Sortie D0 Sortie D1 Sortie Clock Sortie...

Страница 4: ...e La CU elle seule consome 400mA D pendant de l installataion l installateur doit calculer l alimentation n cessaire Note 2 M me tension que l entr e Note 3 R sistance de pull up 1K Note 4 Consultez l...

Страница 5: ...EADER 2 RL1 RL2 RL3 RL4 C NC NO C NC NO C NC NO C NC NO BUS485 Ethernet 10Base T 100Base TX ON 12VDC Input A B 12VDC Output 1A Power Input 12VDC 1A GND GND A B Model CU42E0 Model CU42xx UBOX 4000 MODE...

Страница 6: ...er guide assign the IP address to the UBOX4000 3 Adress the CU42E0 3 1 Press the CLR BUTTON CU42E0 to detect the readers Check that the reader s LEDs blink and the BUS485 LEDs are switched ON 3 2 The...

Страница 7: ...manual de usuario de usuario de SALTRO ProAccess SPACE 3 Direccionar la UBOX4000 3 1 Pulsaci n corta del CLR para detectar los lectores Comprobar que los LEDs de los lectores y el BUS485 est n encendi...

Страница 8: ...Adresser la UBOX4000 3 1 Appuyer sur la touche CLR pour d tecter les lecteurs V rifier que les voyants des lecteurs clignotent et que les voyants du BUS485 sont allum s 3 2 Le UBOX4000 est un appareil...

Страница 9: ...o no est correctamente alimentado comprobar la fuente de alimentaci n NARANJA INTERMITENTE modo direccionamiento OFF sin alimentaci n BUS485 ON UBOX4000 Por definir OFF UBOX4000 Por definir TAMPER ON...

Страница 10: ...C NC NO C NC NO BUS485 Ethernet 10Base T 100Base TX ON 12VDC Input A B 12VDC Output 1A Power Input 12V DC 1A GND GND A B Model CU42E0 104 4 1 8 121 4 3 4 43 1 11 16 10 3 8 44 1 3 4 131 5 3 16 4 32 Mo...

Страница 11: ...er input poort beschermd door een 1A zekering BUS485 Ingangen Installateur moet vaststellen welke kabel nodig is afhankelijk van de input configuratie Indien geen deursensoren of sabotagecon tact gebr...

Страница 12: ...ng Data Ausgang TX Ausgang TX Ausgang Wiegand Omron RS232 Die Widerst ndswert k nnen via Software definiert werden 1k5 2k2 3k3 4k7 6k8 10k Ingangen Ingangen onder toezicht CUADAP en lezers van derden...

Страница 13: ...Schwarz Zwart Svart 2 1 READER_2 READER_1 READER_2 READER_1 Gleiches Paar Hetzelfde paar Samma par B A Mindestabstand zwischen Lesern 20in 50 cm Minimale afstand tussen de lezers 20in 50 cm Minsta avs...

Страница 14: ...gebruik wordt gemaakt van de 12 V uitgang De controller alleen verbruikt 400mA Afhankelijk van de aangesloten componenten moet de installateur een geschikte voeding berekenen en plaatsen Opm 2 Evenve...

Страница 15: ...aster einmal kurz wenn der Sabotagekontakt offen ist Die LED s m ssen einmal kurz aufleuchten 3 2 CU42E0 ist DHCP Vorbereitet In Werksauslieferung ist der DHCP Modus aktiviert Wenn der Kunde keinen DH...

Страница 16: ...tellingen en ken het IP adres toe aan de CU42E0 in de software 3 Adresseer de CU42E0 3 1 Klik de CLR knop kort in om de aangesloten lezers te detecteren controleer of de oranje led op de lezers geknip...

Страница 17: ...er St ll in dip switcharna f r alla CU4200 och tilldela IP adress till CU42E0 3 Adressera CU42E0 3 1 Tryck p CLR knappen CU42E0 f r att detektera l sarna och den anslutna CU4200 Kontrollera att l sarn...

Страница 18: ...De controller is juist gevoed KNIPPEREND ROOD De controller is niet juist gevoed controleer de voeding KNIPPEREND ORANJE adressering modus UIT Geen voeding BUS485 AAN op UBOX4000 Worden gedefinieerd U...

Отзывы: