background image

Model WS / SBI-140 Indicator 

User Manual 

 

10

 
Selecting Unit of Measure 

  
  

 

            

 

 
 
 

Using the Tare 

 

1.

 

 

 

 

 

 

 

 

 

 

 

 
 

 

 

 

 

 

2.

  

 

 

 

 

 

 

 

 

 

 

 

 

3. 

 

 

  

 

 

 

 

 

4.

 

  

 

 

 

 

 

 

 
 
Removing the Tare 

 
 

  

 

.

 

 

 

 

 

 
 
 

 

kg 

 lb 

 lb.oz.

Содержание SBI-140

Страница 1: ...Model WS Range Model SBI 140 Indicator User Manual 11 January 2007 AWT35 000056 Issue B AWT35 000056...

Страница 2: ...Model WS SBI 140 Indicator User Manual 2...

Страница 3: ...l Limited and is supplied without liability for errors or omissions No part may be reproduced or used except as authorised by contract or other written permission The copyright and the foregoing restr...

Страница 4: ...of Measure 10 Removing the Tare 10 Hold Function Automatic Zero on Next Weigh 11 Hold Function Manual Release 11 Removing Hold 12 Print Function 12 Serial Interface Settings 12 Error Messages 13 User...

Страница 5: ...arrying out any routine maintenance To avoid the risk of the machine falling where applicable ensure that it is placed securely on a flat and level surface Safe use Caution Cleaning the indicator weig...

Страница 6: ...odel WS SBI 140 Indicator User Manual 6 Setup Instructions Desk Wall Bracket By changing the angle blocks as shown below the indicator bracket can be converted into a wall mounting bracket Power Suppl...

Страница 7: ...Model WS SBI 140 Indicator User Manual 7 Installing Batteries Connecting Indicator to Platform If necessary wire the cable attached to the base as shown...

Страница 8: ...er Manual 8 General Operating Instructions Display Function Keys Annunciators On Off Zero Activate the tare Select unit Hold Print Centre of zero Net weight displayed Hold activated kg lb oz Active un...

Страница 9: ...Model WS SBI 140 Indicator User Manual 9 Manual symbols Short key press Multiple key press Long key press Indicator Operation Turning On and Zeroing the Indicator 1 2 Turning off the Indicator...

Страница 10: ...Model WS SBI 140 Indicator User Manual 10 Selecting Unit of Measure Using the Tare 1 2 3 4 Removing the Tare kg lb lb oz...

Страница 11: ...11 Hold Function Automatic Zero on Next Weigh 1 HOLD kg 2 HOLD kg HOLD kg 3 HOLD kg 4 HOLD kg HOLD kg Hold Function Manual Release This function needs to be set up in Parameter P3 1 shown on page 14...

Страница 12: ...to a printer or PC the indicator has to be set up in the following parameters P2 P4 P5 and P6 1 HOLD Zero 0 Net kg 2 3 Print Serial Interface Settings RS232 serial interface wiring Pin xxxxxx xxxxx xx...

Страница 13: ...Recalibrate the scale 0_____ Weight below range for calibrated zero point Remove load before zeroing or Recalibrate the scale _____ Indicates an under range condition Remove all loads and zero the sca...

Страница 14: ...up HOLD 2 Selecting parameter 3 Changing data within parameter HOLD Zero 0 Net kg HOLD Zero 0 Net 4 Saving data HOLD Zero 0 Net kg HOLD Zero 0 Net 5 Exiting setup HOLD Zero 0 Net kg kg Moves flashing...

Страница 15: ...pplied 3 50 Selectable hold window from 3 to 50 divisions Once stable holds display reading within a selectable weight range Must be re pressed to release the hold button P3 0 P3 1 P3 2 P3 3 to 50 P4...

Страница 16: ...T CR Sets up a tare LF H1H2H3 CR ETX U CR Changes the units LF u1u2 CR LF H1H2H3 CR ETX L CR Activates the hold function LF H1H2H3 CR ETX X CR Switches off the scale Indicator switches off Unrecognise...

Страница 17: ...P7 12 4000 P7 23 30000 P7 02 750 P7 13 5000 P7 24 35000 P7 03 800 P7 14 6000 P7 25 40000 P7 04 1000 P7 15 7000 P7 26 50000 P7 05 1200 P7 16 7500 P7 27 60000 P7 06 1500 P7 17 8000 P7 28 70000 P7 07 20...

Страница 18: ...lso display any active tare P14 0 P14 1 P14 2 P15 x Scale Power up when outside the power up zero range Allows the scale to power up and display the following 0 Zero and display in current Gross weigh...

Страница 19: ...ration points 1 HOLD 2 HOLD HOLD 3 HOLD HOLD 4 Enter in calibration weight from 25 to 100 full capacity 5 HOLD HOLD 6 For single point calibration enter the same weight in again and move to number 7 F...