Display division value in different weight unit that can be used
Calibration
division value
kg lb Lb:oz
(oz)
0.0001lb
Not available
0.0001lb
Not available
0.001 lb
0.0005 kg
0.001 lb
Not available
0.01 lb
0.005 kg
0.01 lb
0.2 oz
0.1 lb
0.05 kg
0.1 lb
2 oz
1 lb
0.5 kg
1 lb
Not available
10 lb
5 kg
10 lb
Not available
0.0002 lb
0.0001 kg
0.0002 lb
Not available
0.002 lb
0.001 kg
0.002 lb
Not available
0.02 lb
0.01 kg
0.02 lb
0.5 oz
0.2 lb
0.1 kg
0.2 lb
5 oz
2 lb
1 kg
2 lb
Not available
20 lb
10 kg
20 lb
Not available
0.0005 lb
0.0002 kg
0.0005 lb
Not available
0.005 lb
0.002 kg
0.005 lb
0.1 oz
0.05 lb
0.02 kg
0.05 lb
1 oz
0.5 lb
0.2 kg
0.5 lb
Not available
5 lb
2 kg
5 lb
Not available
50 lb
20 kg
50 lb
Not available
5.11) P11.x: select the weighing unit that may be chosen by pressing
UNIT
x=0:
only
kg
x=1:
only
lb
x=2:
only
lb:
oz
x=3:
kg
or
lb
x=4: kg or lb: oz
x=5: lb or lb: oz
x=6: kg, lb, or lb: oz
Above setting of units may not be available as per above tables in 5.10
5.12) P12.x: Power-on zero-point range
15
x=0: the range is set to calibration zero point (CAL.P0) +1%FS
x=1: the range is set to calibration zero point (CAL.P0) +2%FS
x=2: the range is set to calibration zero point (CAL.P0) +5%FS
x=3: the range is set to calibration zero point (CAL.P0) +10%FS
x=4: the range is set to calibration zero point (CAL.P0) +20%FS
x=5: the range is set to calibration zero point (CAL.P0) +50%FS
x=6: the range is set to calibration zero point (CAL.P0) +100%FS
x=7:
No
limitation
5.13) P13.x: Zero range for ZERO button after switch on
x=0 Power-on zero-point +1%FS;
x=1 Power-on zero-point +2%FS;
x=2 Power-on zero-point +3%FS;
x=3 Power-on zero-point +4%FS;
x=4 Power-on zero-point +5%FS;
x=5 Power-on zero-point +10%FS;
x=6 Power-on zero-point +20%FS;
x=7 Power-on zero-point +No limitation
x=8 Power-on zero-point +1%FS;
x=9 Power-on zero-point +2%FS;
x=10 Power-on zero-point +3%FS;
x=11 Power-on zero-point +4%FS;
x=12 Power-on zero-point +5%FS;
x=13 Power-on zero-point +10%FS;
x=14 Power-on zero-point +20%FS;
x=15 Power-on zero-point +No limitation
If zero key can be activated, it can clear the tare weight. If zero point is
above the setting range, the indicator will show “0¯ ¯ ¯ ¯”, and if zero point
is below the setting range, “0_ _ _ _” will be shown.
5.14) P14.x: select which zero point will be used when powered on and
weight signal is within the power-on zero-point range:
x=0: Choose current weight as current power-on zero point.
x=1: Choose calibration zero point as power-on zero point
x=2: Choose power-off zero-point as power-on zero point, and
power-off tare weight as current tare weight.
16