Warnings

Cleaning the scale

Installation

For your protection, all mains (110V or 230V) equipment used where

damp or wet conditions may occur, must be supplied from a correctly

fused source and protected by an approved RCD to BS7071 or BS7288

or IEC1008-2-2 BS EN 61008:1995. IF IN DOUBT SEEK ADVICE

FROM A QUALIFIED ELECTRICIAN.

To avoid the possibility of electric shock or damage to the machine,

always isolate from the mains power supply before carrying out any

routine maintenance.

Harsh abrasives, solvents, scouring cleaners and alkaline cleaning

solutions, such as washing soda, should not be used especially on the

display windows. Under no circumstances should you attempt to wipe

the inside of the machine.

The outside of the machine may be wiped down with a clean cloth

moistened with water containing a small amount of washing up liquid.

Make sure that the work surface is firm, steady and free from vibration

and draughts.

To avoid the risk of RSI (Repetitive Strain Injury) it is important to

ensure that the machine is placed on a surface which is ergonomically

satisfactory to the user. In cases where usage is prolonged EN614-1

recommends frequent breaks for the user.

1

Содержание B220

Страница 1: ...B220 User Instructions Brisch number 76103 383 Issue 1 11 07 01 ENGLISH 76103 383 Counting Scale...

Страница 2: ......

Страница 3: ...g a numeric entry 4 4 Creating a tare 4 Creating a keyboard entered tare 4 Cancelling a tare 5 5 Fast sampling 5 Normal sampling 6 Re sampling 6 Keyboard entered item weights 6 Viewing the item weight...

Страница 4: ...tment 10 To Cancel A User Calibration Adjustment 10 Weights For Calibration Adjustment 10 11 Zero Indicator 11 Zero Tracking 12 Automatic Zero Self Balance 12 Standard Filter 12 Intelligent Filter Set...

Страница 5: ...weight 14 Changing the manual re sampling range 14 Changing the automatic re sampling range 14 14 Changing a PLU item weight 14 Changing a PLU tare 15 Protecting a PLU 15 16 17 Changing PLUs Declarati...

Страница 6: ...abrasives solvents scouring cleaners and alkaline cleaning solutions such as washing soda should not be used especially on the display windows Under no circumstances should you attempt to wipe the in...

Страница 7: ...the scale caused by leaking batteries remove flat or damaged batteries immediately When you see the symbol flashing on the display then you must either replace the batteries or recharge the rechargea...

Страница 8: ...Battery failure Recharge or replace the batteries E 11 Power supply voltage is too high E 15 Contact your authorised service agent E 20 Weight error Remove all items from the weighplate and press the...

Страница 9: ...g a keyboard entered tare 0 000 CE Long press Using the clear key To clear all active PLUs tares and item weights Clearing a numeric entry Enter value 1 26 1 2 0 CE Short press To clear the last entry...

Страница 10: ...g Fast sampling See management mode When sampling items that have a large weight variation it is advisable to use a large sample size and either manual or automatic re sampling Fast sampling The great...

Страница 11: ...t to the scale and then re sample This will increase the sample size and improve the counting accuracy 1 345 10 2 690 20 Long press Sample the items as shown above See management mode Page 14 for deta...

Страница 12: ...ng Reverse counting Short press number of items You can set an item limit before or after sampling Short press Short press 300 Item limit 300 CE Short press 1 345 4 Weight Items Sample the items to be...

Страница 13: ...Weight Items Totalising Sample the items to be counted see page 5 0 000 0 NET NET t n 1 250 NET 250 0 128 t n 2 500 Number of transactions Total or Note Components of different piece weights can be ad...

Страница 14: ...LU hot key Programming a keyboard PLU And or Sample or enter an an item weight Long press Long press Whatever tare and or item weight is active will be entered into the selected PLU hot key And or Sam...

Страница 15: ...pacity Any weight in 1kg steps 15 30kg capacity Any weight in 1kg steps above a minimum of 12 of scale capacity To Cancel A User Calibration Adjustment C Short press Short press Short press Weights Fo...

Страница 16: ...turn to Branch 00 Long press Increment the value short press Increment the value X10 long press Change the value short press Note After changing a value you must go to the next branch to accept the va...

Страница 17: ...6 01 7 Zero Tracking This is used to account for minor weight changes due to temperature variations Standard Filter Filter level 1 6 Default 4 6 08 4 6 11 0 Filter reset 1 255 divisions Disabled Weigh...

Страница 18: ...0 Quiet Loud 1 19 04 1 0 always off 1 5 seconds 2 1 minute 3 5 minutes always on 4 20 00 1 Changing the backlight time Go to branch 20 Sub branch 00 0 none 1 1 minute 2 5 minutes 3 30 minutes 20 01 1...

Страница 19: ...ranch 61 Sub branch 01 61 01 100 0 Manual re sampling off 100 1000 of initial sample size 150 Changing the automatic re sampling range Go to branch 61 Sub branch 02 61 02 100 0 Automatic re sampling o...

Страница 20: ...ber For example PLU5 105 02 145 Sub branch 02 Enter the weight kg Sub branch 03 Enter the number of decimal places 105 03 2 Protecting a PLU Go to the PLU branch number For example PLU5 105 04 1 Sub b...

Страница 21: ...ents up to 10 s disturbance of display There will be no permanent change of operating state or data A copy of the original signed declaration for this instrument is available from PO Box 9533 Smethwic...

Страница 22: ...verified by the manufacturer with a certificate of conformity issued by a notified authority or A copy of the original signed declaration for this instrument is available from PO Box 9533 Smethwick We...

Отзывы: