background image

5

4.0

Scale Operation

This section covers the various scale operations, such as weighing, counting, 

accumulation, etc.

Simple Weighing

1.

Turn the scale on and zero the display, if necessary, by pressing the 

Zero

 

key. Be sure the scale is displaying weight in your preferred unit of 

measure. Change it using the 

Units

 key, if necessary.

2.

Place item(s) to be weighed on the scale…

Weight of the item(s) is displayed in the WEIGHT window.

3.

Remove the item(s) from the scale and repeat steps 1-3 to weigh the 

next item(s).

Tare Weighing

If you want to do net weighing, such as weighing objects in a container, follow 

these steps:

1.

Turn the scale on and zero the display, if necessary, by pressing the 

Zero

 

key. Be sure the scale is displaying weight in your preferred unit of 

measure. Change it using the 

Units

 key, if necessary.

2.

Place the item to be tared (usually a container) on the scale…

Weight of the item is displayed in the WEIGHT window.

3.

Press the 

Tare

 key…

The weight is tared, 

0

 weight is displayed and the 

Tare

 annunciator 

lights.

4.

Place item(s) to be weighed on the scale…

Net weight of the item(s) is displayed.

5.

To remove a tare, remove everything from the scale platform and press 

the 

Tare

 key…

weight is displayed and the 

Tare

 annunciator light turns off. The unit 

is now in gross weighing mode.

6.

Repeat the steps above for other tare weighments.

Содержание B 130

Страница 1: ...p n AWT35 500632 issue AA July 2010 MODEL B 130 Counting Scale User Manual...

Страница 2: ...CTRICAL WARNINGS MEAN THAT FAILURE TO FOLLOW SPECIFIC PRACTICES OR PROCEDURES MAY RESULT IN ELECTROCUTION ARC BURNS EXPLOSIONS OR OTHER HAZARDS THAT MAY CAUSE INJURY OR DEATH WARNING This is a Warning...

Страница 3: ...power cable supplied with the unit DANGER RISK OF ELECTRICAL SHOCK NO USER SERVICEABLE PARTS REFER TO QUALIFIED SERVICE PERSONNEL FOR SERVICE CAUTION The power cable must be connected to an earth gro...

Страница 4: ...nce Always turn off the machine and isolate from the power supply before starting any routine maintenance to avoid the possibility of electric shock Make sure that it is placed securely on a flat and...

Страница 5: ...lass A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial enviro...

Страница 6: ......

Страница 7: ...rminal and the black wire to the black battery terminal Place battery in the compartment with the padding placed as shown and replace the battery cover and tighten the screw Note To improve battery li...

Страница 8: ...s lights when a tare is in effect Weight displayed is net weight kg This lights when the unit of measure in the WEIGHT display is kilograms lb This lights when the unit of measure in the WEIGHT displa...

Страница 9: ...0 of capacity an empty container or weight not required in thecalculation of anaverage piece weight Use of tare will reduce the scale s maximum weight capacity by the tare value stored Accu Used to ad...

Страница 10: ...objects in a container follow these steps 1 Turn the scale on and zero the display if necessary by pressing the Zero key Be sure the scale is displaying weight in your preferred unit of measure Chang...

Страница 11: ...lays the number entered If the piece weight window shows SPL PCS press the CLEAR key and increase your sample weight Counting by Sampling Follow these steps to count items using the sampling method Fo...

Страница 12: ...Entering a Known Piece Weight You can enter a known piece weight and begin counting without sampling This can also be used with the tare function active After you have setthe piece weight place the it...

Страница 13: ...e scale on and zero the display if necessary using the Zero key Be sure the scale is displaying weight in your preferred unit of measure Change it using the Units key if necessary 2 Use sampling or en...

Страница 14: ...nt is displayed press the Accu key to accumulate the count to memory The count is added into memory and temporarily Add is displayed in the WEIGHT window the number of accumulations is displayed in th...

Страница 15: ...e condition before you can count more items and perform a successful accumulation again 5 0 Calibration You should periodically calibrate your scale to ensure accuracy Follow these steps to calibrate...

Страница 16: ...in the WEIGHT window 3 Remove all weight from the scale wait for the scale to be stable the Unit annunciator stops flashing and press the Enter key to capture the zero point If the scale successfully...

Страница 17: ...d in the PIECE WEIGHT window and the A to D counts code is displayed in the COUNT window Vol stands for voltage and X X is the current voltage of the battery If no battery is installed or the connecti...

Страница 18: ...y 2 Key in the number of minutes of scale inactivity that will trigger the auto off function and press the Enter key to accept this value The scale returns to normal mode 8 0 Setting LED Brightness Yo...

Страница 19: ...Err There is an error in calibration maybe the loaded weight is too small or the input weight is not correct Ad Input signal of ADC is over max range Ad _ _ _ _ Input signal of ADC is below min range...

Страница 20: ...drops below 5 5V the scale beeper will sound and work for approximately two minutes before powering off When the scale is powered by the AC adapter the AC annunciator will turn on When the battery is...

Страница 21: ...16...

Страница 22: ...0 444 6132 Fax 44 0 870 010 2241 Email sales salterbrecknell co uk Web Site www averyweigh tronix com USA Salter Brecknell Weighing Products USA 1000 Armstrong Drive Fairmont MN 56031 Toll free 800 63...