background image

Important Considerations

Electrical Service

A 110V, 60HZ, 15AMP GFCI protected ground must be used to supply power to each indivisual pedicure spa.  And the main circuit 

breaker MUST be at 25AMP for maximum of two unit.

Water Supply

All plumbing connections must conform to local codes.

Water supply to the spa should be provided with adequate water pressure and water temperature.

   - Water pressure

       To fill the basin correctly up to level, Normal water pressure should be between 30 to 80 P.S.I.

   - Water temperature

       The hot water supply temperature must not exceed 140

. Adjust your hot water accordingly.  For hot and cold water supply        

       fittings and drain fittings location, see below diagram. Carefully connect the water supply line to the appropriate fittings located  

       on the rear of the pedicure spa.

Backflow Preventive Device

This Device is optional, therefore yot need to order seperately. Salontech does not guarantee the quality of this device.

   - Specification

       Backflow preventive device for faucet: Vacuum breaker comply with ANSI / NSF - 61 - 2000, ASMB A112.18.1 - 2000,

       ASSE1014 and CSA standard - B125.98

        ANSI / ASME A112.18.3M (performance requirements for backflow preventive device and systems in plumbing fixture fittings) is                

        applicable to plumbing fixture fittings with outlets not protected by an air gap. Included in the possible range of applications are          

        fittings with hose connected outlets, fitting with pull out spout, hand held showers, shampoo fittings and deck mounted fittings.

        ASME A112.18.3M is now referenced in ASME A112.18.1M (plumbing fixture fittings) and CSA B125. Backflow preventive devices 

        are listed to both standards with the Canadian Standard Association, IAPMO and UL.

       ANSI - American National Institute.  ASME - American Society of Mechanical Engineers.  CSA - Canadian Standard Association.

       APMO - International Association of Plumbing and Mechanical Officials.  UL - Underwriters Laboratory.

Drain Facilities

The pedicure spa drain must meet local plumbing codes. 

Check valve for Drain (not provided) Must be installed by a licensed 

plumber.

1-1/2” PVC Drain

Outlet

3/8” PIP

Cold Water

Supply Inlet

3/8” PIP

Hot Water

Supply Inlet

Back of the Water Joy Base

Содержание Water Joy

Страница 1: ...Copyright 2010 by Printed in USA Whirlpool Pedicure Spa Manual Joy W a t e r...

Страница 2: ...any damage Failure to note damage on the bill of lading may prevent any claims you may have against the carrier If damage is found you MUST notify the carrier at once and request an inspection DO NOT...

Страница 3: ...Serial Number Order Number Installed BY 79F Express St Plainview NY 11803 Tel 516 433 0900 877 725 6683 Fax 516 433 0977 www salontechspa com info salontechspa com Whirlpool Pedicure Spa Joy W a t e r...

Страница 4: ...device for faucet Vacuum breaker comply with ANSI NSF 61 2000 ASMB A112 18 1 2000 ASSE1014 and CSA standard B125 98 ANSI ASME A112 18 3M performance requirements for backflow preventive device and sys...

Страница 5: ...rest Back Cushion Armrest Footrest Cushion Manicure Tray Polish Tray Due to continuous improvements on all of our products specification characteristics packing color and design are subject to change...

Страница 6: ...m Air Induction System 115V 1 2 Amp 60Hz 55W Each Motor 115V 3 2 Amp 60Hz 110V 120V 60Hz 90W 5Amp 1 2 inch fitting pre installed 3 8 PIP Connection 1 2 inch fitting pre installed 3 8 PIP Connection 1...

Страница 7: ...51 60 29 Joy W a t e r Arm to Arm width 30 5 51 29 16 3 41 25 5 14 5 24 5 22 15 60...

Страница 8: ...st be capable of supporting the occupied pedicure spa For the seat back to full recline the pedicure spa base must be mounted 22 inches from the wall as shown below 51 22 15 7 16 Minimun space require...

Страница 9: ...e r NOTE The requirement for vaccum breaker varies from state to state and province to province Please consult with the licensed plumber 15 6 37 1 5 PVC drain pipe Adjustable P Trap and connector 5 5...

Страница 10: ...re oxygen is being administered Never operate If it has a damaged cord or plug or dropped in the water To disconnect press power button to turn off then remove the plug from the outlet Allow 30 minute...

Страница 11: ...Massage Chair Remote Control Instruction...

Страница 12: ...ater level with one big loop as shown in Fig3 Operation Instruction Please DO NOT run dry 1 Turn to open the drain plug wait 2 seconds 2 Press on off switch to activate the timer 3 After the water has...

Страница 13: ...subject to misapplication improper installation or maintenance neg ligence improper cleaning refurbished or tampered with in any way or other circumstances beyond Salontechspa s control s warranty is...

Отзывы: