background image

8

ENGLISH

• Failure of specified maintenance and repair procedures,

• Risks to persons through electrical, mechanical and

bacteriological effects,

• Property damage.

2.4 Safety instructions for the operator

The existing directives for accident prevention must be adhered to.

Danger from electrical current must be eliminated.

Local  directives  or  general  directives  [e.g.  IEC,  VDE  etc.]  and  local

power supply companies must be adhered to.

This appliance is not intended for use by persons (including children)

with  reduced  physical,  sensory  or  mental  capabilities,  or  lack  of

experience  and  knowledge,  unless  they  have  been  given

supervision  or  instruction  concerning  use  of  the  appliance  by  a

person responsible for their safety.

Children  should  be  supervised  to  ensure  that  they  do  not  play  with

the appliance.

2.5 Safety instructions for inspection and installation work

The  operator  must  ensure  that  all  inspection  and  installation  work  is

carried  out  by  authorised  and  qualified  personnel,  who  are

sufficiently  informed  from  their  own  detailed  study  of  the  operating

instructions.

Work to the product/installation must only be carried out when at a

standstill.  It  is  mandatory  that  the  procedure  described  in  the

installation  and  operating  instructions  for  shutting  down  the

product/unit be complied with.

2.6 Unauthorised modification and manufacture of spare parts

Modifications  to  the  product  are  only  permissible  after  consultation

with  the  manufacturer.  Original  spare  parts  and  accessories

authorised by the manufacturer ensure safety. The use of other parts

can nullify the liability from the results of their usage.

2.7 Improper use

The  operational  safety  of  the  supplied  product  is  only  guaranteed

for conventional use in accordance with section 4 of the installation

and  operating  instructions.  The  limit  values  must  on  no  account  fall

under or exceed those specified in the catalogue/ data sheet.

3. TRANSPORT AND STORAGE

When  receiving  the  material,  check  that  there  has  been  no

damage during the transport. If any defect has been stated, take all

necessary steps with the carrier within the allowed time.

CAUTION! If the delivered material is to be installed later on,

store it in a dry place and protect it from impacts and any

outside influences (humidity, frost, etc...).

4. PRODUCTS AND ACCESSORIES

4.1 Applications

Pumps  for  lifting  of  domestic  waste  water  containing  particle  lower

than 30 mm.

For fixed installation in a sump or a tank.

4.2 Description (See FIG. 1)

1 : Check valve adapted to the conveyed medium.

2 : Isolating valve.

3 : Overflow audible signal.

4 : Pump lifting chain.

5 : Motor cable - length 10 m.

4.3 The pump

- Submersible monobloc electropump.

- Centrifugal single-stage with vortex impeller.

- horizontal or vertical (with bend) discharge port .

- Tightness with lip seal.

1. GENERAL

About this document

The language of the original operating instructions is french. All other

languages  of  these  instructions  are  translations  of  the  original

operating instructions.

These  installation  and  operating  instructions  are  an  integral  part  of

the product. They must be kept readily available at the place where

the  product  is  installed.  Strict  adherence  to  these  instructions  is  a

precondition  for  the  proper  use  and  correct  operation  of  the

product.

These  installation  and  operating  instructions  correspond  to  the

relevant version of the product and the underlying safety standards

valid at the time of going to print.

EC declaration of conformity:

A copy of the EC declaration of conformity is a component of these

operating instructions.

If  a  technical  modification  is  made  on  the  designs  named  there

without our agreement, this declaration loses its validity.

2. SAFETY

These  operating  instructions  contain  basic  information  which  must

be  adhered  to  during  installation  and  operation.  For  this  reason,

these operating instructions must, without fail, be read by the service

technician  and  the  responsible  operator  before  installation  and

commissioning.

It  is  not  only  the  general  safety  instructions  listed  under  the  main

point  "safety"  that  must  be  adhered  to  but  also  the  special  safety

instructions  with  danger  symbols  included  under  the  following  main

points.

2.1 Indication of instructions in the operating instructions

Symbols :

General danger symbol.

Danger due to electrical voltage.

NOTE:

Signal words:

DANGER! 

Acutely dangerous situation

Non-observance results in death or the most serious of injuries.

WARNING!

The user can suffer (serious) injuries. 'Warning' implies that (serious)

injury to persons is probable if this information is disregarded.

CAUTION!

There is a risk of damaging to the product/installation.

'Caution' implies that damage to the product is likely if the

information is disregarded.

NOTE: Useful information on using the product. It draws attention to

possible problems.

2.2 Personnel qualifications

The  installation  personnel  must  have  the  appropriate  qualifications

for this work.

2.3 Danger in the event of non-observance of the safety instructions

Non-observance of the safety instructions can result in risk of injury to

persons and damage to product/installation. Nonobservance of the

safety instructions can result in the loss of any claims for damages.

In  detail,  non-observance  can,  for  example,  result  in  the  following

risks:

• Failure of important functions of the product/installation,

Содержание PRIMA WASTE

Страница 1: ...PRIMA WASTE N M S STOCK N 4 152 292 Ed 1 09 10 FRANCAIS ENGLISH INSTALLATION ET MISE EN SERVICE INSTALLATION AND STARTING INSTRUCTIONS...

Страница 2: ...2...

Страница 3: ...3...

Страница 4: ...B min h1 h h2 1 A 2 4 3 1 230V 1 230V 50 Hz 5 FIG 1 4...

Страница 5: ...rieures 30 mm Utilisation en installation fixe dans un puisard ou dans un r servoir 4 2 Descriptif Voir FIG 1 1 Clapet anti retour adapt au fluide v hicul 2 Vanne d isolement 3 Alarme sonore de trop...

Страница 6: ...pr sent assur automatiquement par l interrupteur flotteur ou les r gulateurs de niveaux 7 ENTRETIEN Aucun entretien particulier en cours de fonctionnement toutefois on peut tre amen d gager la cr pine...

Страница 7: ...n en cas de remplacement bien raccorder les conducteurs entre eux en fonction des couleurs c D monter la roue et la nettoyer a D monter et nettoyer la tuyauterie b Voir 8 1 c c V rifier le sens du mon...

Страница 8: ...ignal 4 Pump lifting chain 5 Motor cable length 10 m 4 3 The pump Submersible monobloc electropump Centrifugal single stage with vortex impeller horizontal or vertical with bend discharge port Tightne...

Страница 9: ...rvicing while the pump runs but cleaning the impeller or the strainer can be necessary ATTENTION Before any intervention disconnect the pump 4 4 The motor Monophase thermal protection with an integrat...

Страница 10: ...release or the switch of the control box b Check the resistances between the cable ends if necessary replace the cable Caution in case of replacing reconnect correctly the supply wires according to th...

Страница 11: ...11 NOTES...

Страница 12: ...za SALMSON ITALIA Via J PeriI 80 I 41100 MODENA ITALIA TEL 39 059 280 380 FAX 39 059 280 200 info tecniche salmson it W S L LEBANON Bou Khater building Mazda Center Jal El Dib Highway PO Box 90 281 Dj...