![salmson LIFTSON M-2V-208 Скачать руководство пользователя страница 25](http://html1.mh-extra.com/html/salmson/liftson-m-2v-208/liftson-m-2v-208_installation-and-starting-instructions_3652024025.webp)
English
Installation and operating instructions Liftson M-2V-208
25
Please state all the information on the unit name plate when ordering spare parts.
5.3 Scope of delivery
Sewage lifting unit, including:
Switchgear (1~ 230 V/3~ 400 V),
1 inlet seal DN
100 (for pipe Ø 110 mm)
1 keyhole saw Ø 124 for inlet, DN
100
1 PVC hose section, Ø 50 mm, with clamps for inlet port, DN
50
1 special lip seal for suction pipe connection of diaphragm hand pump, DN
50
1 collar for ventilation connection, DN
70
1 set of fixation material
11 sound absorption strips for insulation of structure-borne noise
1 DN
80/100 flange piece with flat gasket, flexible hose section, hose clips, screws and
nuts for connecting the pressure pipeline, DN
100
1 set of installation and operating instructions
5.4 Accessories
Accessories must be ordered separately.
The following accessories are available:
• Flange piece DN
80, DN
80/100 (1 x DN
80/100 already included in the scope of delivery),
DN
100, DN
150 for connecting the slide valve on the inlet or pressure side to the pipe
• Inlet seal for additional inlet, DN
100 (one is already included in the scope of delivery)
• Connection set for inlet, DN
150 (curve cutter, inlet seal)
• Gate valve (DN
80) for discharge pipe
• Gate valve (DN
100, DN
150) for inlet pipe
• Diaphragm hand pump (R 1½) (without hose)
• 3-way cock for switching over to the manual suctioning from the pump sump/tank
• Alarm switchgear
• Rechargeable battery (NiMH) 9 V/200 mAh
• Horn 230 V/50 Hz
• Flashing light 230 V/50 Hz
• Signal lamp 230 V/50 Hz
Max. total delivery head
[mWS]
8.5
Max. permitted geodesic delivery head
[mWS]
6.5
Max. permitted pressure in the pressure
pipeline
[bar]
1.5
Max. volume flow
[m³/h]
35
Max. fluid temperature
[°C]
40 (60 °C, 3 min)
Max. ambient temperature
[°C]
40
Max. solid grain size
[mm]
45
Sound pressure level
(depending on duty point)
[dB(A)]
< 70 *
1)
Gross volume
[l]
115
Switching volume
[l]
40
Dimensions (WxHxD)
[mm]
810x505x780
Net weight
[kg]
91
Pressure connection
[DN]
80
Inlet ports
[DN]
40, 100, 150
Ventilation
[DN]
70
*
1)
Improper system and pipe installation, as well as impermissible operation, can increase
the acoustic emissions.
CE
09
EN 12050-1
Faeces lifting unit for buildings, DN
80
Lifting power
- see pump curve
Noise level
- < 70 dB(A)
Corrosion
protection
- coated, or corrosion-resistant
materials Inox/composite
5.2
Technical data
Содержание LIFTSON M-2V-208