SETTING THE GAS PRESSURE
Fit a manometer with a 6 mm rubber hose to the test point on the regulator (for natural gas).
Use Light Wok and Auxiliary burner and adjust test point pressure to 1.00 kPa. Turn the two burners off
and on again and recheck the pressure is same as set previously or adjust as required.
TEST FOR CORRECT OPERATION
After installation and test point setting, each burner ignition and operation must be tested individually
and with all burners operating. Ignite all burners both individually and concurrently to ensure correct
operation of gas valves, burners and ignition. Turn gas taps to low flame position and observe stability
of the flame for each burner individually and concurrently. This testing must be done by the installer
before leaving.
Check that the duplicate data plate sticker (supplied in separate bag) has been fitted on a surface adja-
cent to the hotplate, for example, the inside of the cupboard door so it is clearly visible.
ADJUSTING THE BURNER MINIMUM FLAME HEIGHT
NOTE: This adjustment can only be performed by authorised service personnel.
The minimum burner flame is factory adjusted for the gas type stated on the gas type label adjacent
to the gas connection and should not require adjustment. Adjustment may be required if the hotplate
has been converted from Natural gas to Universal LPG or vice versa.
GAS CONVERSION INSTRUCTIONS
The manufacturers servicing instructions detail how authorised personnel may convert the hotplate
from Natural gas to Universal LPG or from Universal LPG to Natural gas. Contact the manufacturer or
agent as required.
ELECTRICAL CONNECTION
•
WARNING:
Disconnect mains power before installing appliance failure to do so can result in death
or electrical shock.
•
Install in accordance with relevant electrical standards and/or codes of practice applicable.
•
Before connecting, check the system and electrical sockets amperage is adequate for the appli-
ance’s maximum power (see data label affixed on the bottom of the appliance).
•
The electrical safety of this appliance is only guaranteed if it is correctly connected to a good
earth system or socket, as prescribed by the electrical safety standards.
•
Ensure that the power supply voltage falls within the values indicated on the data plate.
•
Fit to the power cable (C) with a standardized plug, suitable for the load which is indicated on the
data label.
•
For connecting do not use reductions, adapters or shunts as they could cause false contacts
resulting in hazardous overheating.
•
The appliance and connection must be positioned so that once the appliance has been installed,
the power supply cable and the electrical socket should be easily accessible.
•
Do not use extension cables or multiple socket adapters.
WARNING!
Installation of this appliance should only be attempted by an
authorised installer following local laws and regulations.