6
1.2.3.2. To keep in mind.
•
Do not try to dismantle or change any part of the
equipment, if this action is not contemplated in this
document. Manipulation inside the SPS due to any modifica-
tion, reparation or any other cause, can make an electrical
discharge of high voltage and it is restricted to qualified staff
only. Do not open the equipment.
A part from the implicit stated risks, any action that make the
modification, internal or external of the equipment or just only
the simple intervention inside of itself, which is not stated in
this document, it can expire the warranty.
•
If it is observed that the SPS exhausts smoke or toxic gas,
shutdown it immediately and disconnect it from the power
supply. This kind of fault can cause fire or electrical dis-
charge. Contact with our
(
S.T.S.
)
.
•
In case of an accidental equipment dropping or if the enclo-
sure is damaged, do not start it up under any concept. This
kind of fault can cause fire or electrical discharge. Contact
with our
(
S.T.S.
)
.
•
Do not cut, manipulate the electrical cables, do not put heavy
objects over them too. Any of these actions could cause a
short-circuit and make a fire or electrical discharge.
Check that the electrical cables of connection, plugs and out-
lets are in good conditions.
•
When moving an equipment from a cold place to a warm en-
vironment and vice versa, it can cause condensation (small
water drops) in the external and internal surfaces. Before in-
stalling a moved equipment from another place or even pack-
aged, the equipment will be left for a minimum time of two
hours in the new location before making any action, with the
purpose of adapting it to the new environmental conditions
and avoid the possible condensations.
The SPS has to be completely dry before starting any instal-
lation task.
•
Do not store, install or expose the equipment in corrosive,
wets, dusty inflammable or explosive environments and
never outdoors.
•
Avoid to locate, install or store the equipment in a place with
direct sunlight or high temperatures. Batteries could be dam-
aged.
In the exceptional case and long exposition to intense heat,
batteries can cause filtrations, overheating or explosions,
which can cause fires, burn or other injuries. High tempera-
tures can also make deformation in the plastic enclosure.
•
The location will be spacious, airy, away from heat sources
and easy access.
•
Do not obstruct the cooling grids by entering objects through
themselves or other orifices.
•
Leave as minimum space of 25 cm in the equipment pe-
ripheral.
•
Do not put materials over the equipment or parts that obstruct
the correct visualization of the synoptic.
•
Be careful to not wet it, because it is not waterproof. Do not
allow entering any kind of liquids in. If accidentally the outside
of the machine comes into contact with liquids or salt air, dry
it with a soft and absorbent cloth.
•
To clean the equipment, wipe over a damp cloth and then
dry it. Avoid sprinkling or spillage that could enter through the
slots or cooling grids, which may cause fire or electric shock.
Do not clean the equipments with products that could have
alcohol, benzene, solvent or other inflammable substances,
or they are abrasive, corrosive, liquids or detergent.
•
When it is needed to remove the protection cover to access
to the terminals, they will have to be put back before starting
up the equipment. Otherwise you may incur personal injury
or equipment damage.
•
Be careful to not lift heavy loads without help, according to
the following recommendations:
, < 18 kg.
, 18 - 32 kg.
, 32 - 55 kg.
, > 55 kg.
•
SPS are electronic equipments, so they will be treated as
they are:
Avoid shocks.
Avoid jolting or bouncing of the SPS, like those produced
by moving the equipment on a hand truck and move on
an uneven or wavy surface.
•
SPS transport will be done packaged inside its original pack-
aging in order to prevent it from shock and impact and by
means of the suitable type of packaging (carton box, pallet
packaging, ...) and appropriate to its weight.
•
Although the physical location of the elements can differ from
the illustrations in this manual in some cases, the correct la-
belling correct the possible doubts and makes easy its com-
prehension.
1.2.3.3. Safety warning regarding batteries.
•
The manipulation and connection of the batteries
shall be done and supervised by personnel with
battery knowledge only.
Before doing any action, disconnect the batteries. Check that
no current is present and there is not dangerous voltage in
the DC BUS (capacitors) or in the endpoint of the battery set
terminals.
Battery circuit is not isolated from input voltage. Dangerous
voltages can be found between the terminals of the battery
set and the earth. Check that there is not any voltage at the
input before take any action over them.
•
When faulty batteries are replaced, the complete battery set
has to be replaced, less exceptional cases in new equip-
ments, were due to manufacturing faults it will only be re-
placed the defective ones.
The replacement will be done by another one of the same
type, voltage, capacity, quantity and brand. All of them has to
be of the same brand.
•
Generally, the used batteries are sealed lead acid of 12V and
maintenance free (VRLA).
•
Do not reuse the faulty batteries. There could be an explo-
sion or burst any battery with the involved problems and is-
sues that could happen.
•
Generally supplied batteries are installed in the same cab-
inet, case or rack of the equipment. Depending on the power,
autonomy or both, they can be supplied separately from the
equipment in another cabinet, case or rack, with the interlink
cables among them. Do not modify its length.
•
In those equipments requested without batteries, their ac-
quisition, installation and connection of themselves will be
done by the end-user and under his responsibility. Data
concerning the batteries as regards to quantity, capacity and
voltage, are stated in this battery label sticked beside the
nameplate of the equipment. Respect these data, battery
connection polarity and the supplied circuit diagram strictly.
USER MANUAL