2.  INSTALLATION AND STARTUP.

1. 

Insert the NIMBUS card into the appropriate slot of the 

device. It needs to be well inserted. 

The card will be powered directly by the device, meaning 

that no external power is necessary. If the card has been 

correctly inserted, the power LEDs will light up. See the red 

box in Fig. 2.

 

Fig. 2. 

NIMBUS card inserted into its slot

2. 

Connect one end of an RJ45 cable to the card and the other 

end to the Ethernet socket. The RJ45 port lights on the card 

should light up. See the red box in Fig. 3.

Fig. 3. 

Connection of the RJ-45 cable

3. 

Once the NIMBUS card is correctly powered by the device, 

it will be ready for use. The NIMBUS card will come with 

the latest available version already installed by default.

Once the NIMBUS card protective cover is in place, it 

should look like the image shown in Fig. 4.

Fig. 4. 

The NIMBUS card with protective cover in place.

2.1.  INITIAL CONNECTION

Important

: The card has a preset IP address to enable initial 

connection. This address is fixed and always available; how-

ever, it is necessary to configure a secondary IP address in order 

to use the card correctly.

Once the NIMBUS card has been correctly installed in the de-

vice via the corresponding slot, an available IP address must 

then be correctly configured in order to gain remote access to 

the card’s onboard panel. 

2.1.1.  Point-to-point connection (Ethernet cable).

The fixed IP is always available at the address 100.0.0.1.

To access it, connect one end of the Ethernet cable to the dedi-

cated slot on the NIMBUS card and the other end to your com-

puter. 

Configure the point-to-point connection by accessing network 

connections and creating a new connection with the following 

parameters:

After you have correctly created the point-to-point connection, 

you should be able to access the NIMBUS card via this IP ad-

dress. If you access the card via this address, you can change 

the card’s final address in the panel’s ‘Network’ section (

3.6.1. 

Network

).

2.2.  INITIAL CONFIGURATION

The NIMBUS card comes configured with the necessary param-

eters to enable the panel and all of its functionalities to be used 

satisfactorily.

These are the following: 

 

Auto-configuration of the device into which it is incorpo-

rated.

 

NTP servers.

 

Active communication services (MODBUS, TCP and SNMP).

 

IP address by DHCP 

(default)

.

 

Active RTC.

 

MODBUS address of the default slave to 1.

Any of these parameters can be modified at any time. For more 

information, see section 

‘3.6. System (only for the Adminis-

trator)’

Keep in mind that modifying some parameters could 

cause the panel to behave incorrectly. Do not modify 

them if you are unsure of your actions.

Содержание NIMBUS

Страница 1: ...USER MANUAL NIMBUS Card...

Страница 2: ...2...

Страница 3: ...only for Administrator and Engineer users 3 5 3 1 ADAPT X Series 3 5 3 2 CUBE3 CUBE3 Series 3 5 3 3 X PERT Series 3 5 3 4 DC S Series 3 5 4 Metrics 3 5 5 Manage alarms DC S series only 3 5 6 Actions D...

Страница 4: ...remote maintenance service that provides real time information about the current status of the device Remote communication with the device enables maintenance and repair work to be carried out withou...

Страница 5: ...o offers the possibility of receiving notification alerts whenever an event or alarm occurs in the device either through the same web page or via email The remote maintenance with the web panel also o...

Страница 6: ...available IP address must then be correctly configured in order to gain remote access to the card s onboard panel 2 1 1 Point to point connection Ethernet cable The fixed IP is always available at th...

Страница 7: ...s It is only necessary to import the certificate once with any of the browsers The system will save the certifi cate for all of them If the certificate has already been imported into the computer and...

Страница 8: ...t A screen similar to the one shown in Fig 10will appear Click on Import Fig 10 Import window The system will require the password of your computer before proceeding When prompted for the label enter...

Страница 9: ...message will no longer be displayed Fig 14 Accept risk and continue window 3 1 1 3 Chrome Opera The first time you access the panel the following screen will be displayed Fig 15 Chrome Opera browser...

Страница 10: ...g 19 Fig 19 Certificate viewer screen Once this step is finished the certificate will have been imported correctly Restart the browser to confirm it In Settings navigate to the bottom of the page acce...

Страница 11: ...IP field you will find the address to enter in the browser 3 If the card does not have a static address it will be as signed one automatically as soon as you connect the RJ45 cable 3 1 3 Supported bro...

Страница 12: ...e other options will be shown To avoid long navigation trees which can lead to confu sion only one overall section at a time can be displayed Within the section Device you can continue to display the...

Страница 13: ...active and shows no errors For the battery full charge Yellow only for the battery The battery is in discharge or the charge is less than 100 Grey No current is flowing through that element or part of...

Страница 14: ...29 Diagram relating to a single module 3 4 2 Alarms At the bottom of the screen the different blocks of alarms that the device has and its current status are shown block 3 Non active alarms are shown...

Страница 15: ...odify only the non critical parameters of the device Important For some devices it is not possible to modify certain parameters if the required circumstances are not met Refer to section 3 5 3 x for m...

Страница 16: ...knowledged again 3 5 6 Actions DC S series only In this section it is possible to force actions on the device al though at present only the battery test is available When it is possible to launch an a...

Страница 17: ...u must first refer to the section 4 In stalling the RCCMD software Specify the IP address of the destination server here If you wish to broadcast enter the broadcast IP You must also add the port of t...

Страница 18: ...in order to read information as well as the parameters of the protocol for establishing a connection to the device By default these values already enable correct communication with the device If you w...

Страница 19: ...HE SOFTWARE Open a browser window and go to https www generex de From there click on the Download tab and make sure that below the Software section there is a section titled RCCMD Now click on the but...

Страница 20: ...elected this operating system you will need a li cence code which will be provided by SALICRU Once you have the code and have selected the desired oper ating system click on the Create package button...

Страница 21: ...e NIMBUS card To enter an IP click on the Insert button as shown in the image A pop up window will appear as shown in Fig 56 Fig 56 Insert IP screen In the corresponding field enter the IP of the NIMB...

Страница 22: ...IN THE CLOUD There are two ways to register the device in the cloud using the portal and using a QR code 5 1 1 Nimbus portal 1 Go to https nimbus salicru com 2 To register the product you will need t...

Страница 23: ...y if you have registered other SALICRU devices you can use this field to easily differentiate between them The device s location and the corresponding time zone are both obligatory fields To add the d...

Страница 24: ...Remember to check the Spam folder if you cannot find the email in your inbox After you click on the link contained in the email you will be able to create a new password Click on Save to save changes...

Страница 25: ...essage similar to the one below will appear and the new device will be added to your list of registered devices 5 2 GENERAL TECHNICAL SPECIFICATIONS In the Tab 6 below lists the technical specificatio...

Страница 26: ...26...

Страница 27: ...27 NIMBUS Card USER MANUAL...

Страница 28: ...com SALICRU COM www linkedin com company salicru salicru_SA Product Range Uninterruptible Power Supplies UPS Stabilisers Step Down Light Dimmers Power Supplies Static Inverters Photovoltaic Inverters...

Отзывы: