57
EN
Model
Thermal-
magnetic
circuit
breaker
Differen-
tial relay
Over-
voltage
protection
Previous
fuse. Max.
value
(1/phase)
EQX2 2001-S
2P 16A
Curve C
2P 25A
30mA
Class A
40kA 230V
TT Type II
125 A gL
EQX2 3001-S
2P 20A
Curve C
EQX2 3002-S
EQX2 3002-SX
EQX2 4002-S
2P 32A
Curve C
2P 40A
30mA
Class A
EQX2 4002-SX
EQX2 5002-S
2P 40A
Curve C
EQX2 5002-SX
EQX2 6002-S
EQX2 6002-SX
EQX2 8002-SX
2P 50A
Curve C
2P 63A
30mA
Class A
EQX2 10002-SX
2P 63A
Curve C
Tab. 10. AC circuit breakers
g.
Connect the other end of the hose to the AC circuit breaker
in the junction box, downstream of the connection's IGA.
For the connection of equipment with 24h
monitoring, see manual EL18700.
Fig. 31. Electrical wiring diagram.
6.4. INSTALLATION
OF THE MONITORING DEVICE.
6.4.1. Mechanical installation.
The single-phase inverter of the EQX2 series supports WiFi and
RS485 communications.
Plug the WiFi module into the USB (WiFi) port located at the
bottom of the inverter (as shown in Fig. 32). A "click" indicates that
the module has been fitted correctly.
Fig. 32. Communication device connection (WiFi antenna).
6.5. CT/RS485 CONNECTION.
6.5.1. Description of the terminals.
The inverter's communication ports are located at the bottom and
behind the COM2 board, and include the CT port, RS485 port (used
for the data logger connection), as shown in Fig. 33:
1
1
1
3
5
2
2
3
3
2
4
6
Port 1
Port 2
Port 3
COM2-1
COM2-2
Fig. 33. Communication ports.
Port 1
Port 2
Port 3
CT port
RS485 port
Not used
Port
No.
Function
Selector
no.
Definition
1
Connect the external transformer
for the Zero Injection and
Monitoring function of the EQX2
series inverters.
1
Connect cable S1
2
Connect cable S2
3
Zero.
2
Monitoring / RS485
1
RS 485 A
2
RS 485 B
3
PE / Zero
Tab. 11. Communication ports.
EQX2
SOLAR INVERTERS CONNECTED TO THE GRID