background image

EN |

 23

RIS 400-700 P EKO 3.0 v2019.06

21.4.  RIS 400PW EKO 3.0

1_

74

8-

00

19

A

.0

.1.

0-

L-

0k

P

V

 - s

upp

ly

 a

ir f

an E

C

.

IV

 - 

ex

trac

t air

 fan E

C

.

TL -

 fr

es

h ai

r t

em

per

at

ur

e s

en

sor

.

TJ

 - s

up

ply

 air

 tem

per

at

ur

e s

en

sor

.

D

TJ

100 -

 ex

tra

ct

 air

 te

m

per

at

ur

e an

d hu

m

idit

y

sen

sor

.

TE

 - ex

hau

st

 air

 te

m

per

at

ur

e s

ens

or

.

TV

 - W

at

er

 he

at

er

 ant

ifr

eez

e r

et

ur

hea

t

car

rier

 tem

per

at

ur

e s

ens

or

.

T1 -

 W

at

er

 h

eat

er

 an

tif

ree

ze

 the

rm

os

tat

.

M

1 - BYPASS d

am

pe

r a

ct

ua

to

r.

M

2 -

 ou

ts

ide a

ir da

m

per

 ac

tua

tor

.

M

3 -

 ex

trac

t ai

r dam

pe

r ac

tuat

or

.

M

4 -

 W

at

er

 he

at

er

 c

irc

ula

tor

y pum

p.

M

5 -

 w

at

er

 c

oo

ler

 v

al

ve 

ac

tuat

or

.

M

6 -

 W

at

er

 he

at

er

 v

al

ve 

ac

tuat

or

.

P

 - D

X

 c

oole

r pr

ot

ec

tion

, di

ffer

en

tia

l pr

es

sur

e

sw

itc

h.

P

/U

 - "

Tr

an

ss

m

ite

r 1"

 s

uppl

y a

ir pr

es

sur

e

tra

ns

m

itt

er 

(0

-1

0 VD

C

).

P

/U

 - "

Tr

an

ss

m

ite

r 2"

 ex

trac

t ai

r f

an

 0-

10

V

pr

es

sur

e,

 C

O

trans

m

itt

er

s.

FA

 - f

ire al

ar

m

s in

put

.

P

S

1 -

 s

up

ply

 air

 filt

er

 pr

es

su

re r

elay

.

R

G

1 - c

on

tro

lle

r PR

V-.

.. V2

.5

.

Q

1 -

 d

is

conn

ec

tor

.

F1,

 F

2 -

 fu

ses

 (s

iz

e B

T-

5x

20)

.

X33.

7

X33.

6

X33.

8

DMP

DMP+

DMP-

24VD

C

2

3-

pos

iti

on

13

M1

1 - G

ND

2 - A

C24V

 open

3 - A

C24V

 cl

ose

B

K

W

HR
D

1

2

3

X21

X16.

10

2

1

F1

5A

N

P

E

L1

C

EE7/

7

3x

1,

5

X16.

9

3536

T1

TV

14

24V

D

C

, 0-

10V

D

C

G

Y0

0 -

 G

ND,

Y

 - 0-

10V

,

G

 - 2

4V

DC.

M6

32

X16.

8

33

34

29

30

31

1A

F2

N

L

PE

1f

, 230V

 A

C

X16.

7

M4

PE

X

16

N L1

Jum

per

STA

RT-

NC

STO

P-N

O

BO

OST

PE

X

23

L1

N

2 4

3

1

Q

1

26

 - 24V

 D

C

,

27

 - i

nt

put

, 0-

10

V

 D

C

,

28

 - G

ND,

Tr

ans

m

itt

er

 2 

(24 

V

D

C

)

P

282

7

26

X33.

22

X33.

21

COM 
T.se

t

16

15

X1

6.

2

HR

A4 
A4

PUM

P

AC.

N


N

V1

COM

X12

X42

X37.

2

X37.

1

COM

V2

X37.

3

X37.

4

X4 
X3

M

od

B

us

 R

TU

R

S

485

_2

RS485_2

A1

A1

A2

A2

A3

A3

TE

TE

X52

X33.

19

X33.

20C

OM

T.WA

T

TJ

X33.

22

X33.

21

X35.

3

X35.

4

X35.

5

N

L suppl

y

L cont

rol

N

N

N

EXT+

EXT-

EXT

-

L cont

rol

L (op

en)

AC.

N

EXT+ 
EXT-

X10


L (cl

ose)

X8

L

N

RS485_1

T.OU

T

COM

TJ

R

S

485

_1

R

em

ot

e c

on

trol

R

G1

TA

13

14

22

21

X16.

6

X

16.

5

M2

M3

19

17

18

L

N

NL

L

20

230V AC

230V AC

ON/

OF

F

ON/

OF

F

X37

TL

LOW

X32.

1

CO

M

X32

.4

HIGH

X32.

2

TIME

R

X32.

3

COM

X33.

1

MID

X33.

2

CH

IL

X33

.9

CO

M

X33

.10

A2

A1

R1

87

X16.

3

ALA

RMX

33.11

COM

AN

TI.F

Fan f

all

1.2W

 max

4

56

109

X16.

4

+24

1.2W

 max

Fan r

un

11

12

COM 
FAN

25
24

23 -

 24V

 D

C

,

24 

int

put

, 0-

10V

 D

C

,

25 -

 G

N

D

,

Tr

ans

m

itt

er

 1 (

24 V

D

C

)

P

23

X29

X24

N

L

3

1

P

D

X

 C

ool

ing

B.0.

10

COM

14

11

G

M5

24V

A

C

, 3-

pos

iti

on

Y2

Y1

VAL 
VAL- 
VAL+

X33.

3

X33.

4

X33.

5

3

12

X

16.

1

24V

D

C

Y

1 -

 C

ont

rol

 O

P

E

N

 (A

C

 24 V

)

Y

2 -

 C

ont

rol

 C

LO

S

E

 (A

C

 24 V

)

G

 - S

ys

tem

 pot

ent

ial

 A

C

 24 

V

X35.

2

X35.

1

X33.

13

X33.

14

X33.

18

X33.

12

X33.

17

X33.

25

X33.

26

X34.

1

X34.

2

X34.

3

X34.

4

X34.

5

X34.

6

X34.

7

X34.

8

X40.

1

X40.

2

X40.

3

X38.

2

X38.

1

X39.

1

X39.

2

X41.

2

X41.

1

24VD

C

24VD

C

X31

L

X33

0-

10V

in

-

G

ND

P

V

L

N

PE

+

+

PE

N

L

IV

G

ND

-

0-

10V

in

X3

9

8

7

6

5

4

3

2

1

9

8

7

6

5

4

3

2

1

X32

10

11

12

1

2

3

4

5

6

7

8

9

12

11

10

23

0V AC

, 50H

z

B

K

 - 

bl

ac

k,

R

D

 - 

re

d,

W

H

 - w

hite

.

TA

U

RH

RH

COM

TA

+5V

GY

YE

WH

RD

FA

Jum

pe

r

Содержание RIS 400 P EKO 3.0 Series

Страница 1: ...RIS 400 700 P EKO 3 0 EN MOUNTING AND INSTALLATION INSTRUCTION...

Страница 2: ...8 4 ELECTRICAL HEATER 12 19 AUTOMATIC CONTROL 12 19 1 SYSTEM PROTECTION 13 19 2 USING THE UNIT IN BMS NETWORK 13 19 3 MODBUS ADRESSES 14 19 4 ELECTRICAL CONNECTION OF THE HVAC UNIT 15 19 5 SYSTEM ADJU...

Страница 3: ...IP xx xx kg Made in iauliai Lithuania AHU000000 BN xxxxxx 2019 01 01 Figure 2 2 Technical label place Figure 2 3 Indication for duct connection ODA outdoor air SUP supply air ETA extract air EHA exhau...

Страница 4: ...hich draw air in from the room and duct exhaust gases out through a chimney or extraction ducting The heating appliance can be starved of oxygen impairing combustion In exceptional cases harmful gases...

Страница 5: ...ed min 1 3230 3230 3230 3230 supply power current kW A 0 168 1 4 0 168 1 4 0 168 1 4 0 168 1 4 speed min 1 3230 3230 3230 3230 control input VDC 0 10 0 10 0 10 0 10 protection class IP 54 IP 54 IP 54...

Страница 6: ...o 40 C o 3 C o 40 C o Figure 7 1 With external pre heater operating conditions 5 C o 40 C o 40 C o 40 C o 15 C o 40 C o 5 C o 40 C o 15 C 10 o o C 40 C o 15 C o 40 C o 3 C o 40 C o Figure 7 2 With in...

Страница 7: ...the protective profiles After unpacking the unit examine it to make sure that it it has not been damaged during transportation The installation of damaged units is prohibited Verify that all ordered e...

Страница 8: ...t the unit during transportation It is recommended to remove the film because other wise oxidation signs may occur Before every heating season the condensate tube shall be filled with water as indicat...

Страница 9: ...ensor IV Exhaust fan TE Exhaust air temperature sensor KE1 Electric heater DTJ Extract air temperature and RH sensor PE1 Electric pre heater T2 Cooler changeover thermostat KV2 Water pre heater TV2 Wa...

Страница 10: ...aged during installation all electrical devices are connected to power supply and fit for service all necessary automation elements are installed and connected to power supply and terminal blocks cabl...

Страница 11: ...lerated wear on motor bearings and vibration Clean impeller and inside housing with mild detergent water and damp soft cloth Do not use high pressure cleaner abrasives sharp instruments or caustic sol...

Страница 12: ...re Fans are started at maximum speed and BOOST is displayed in the remote control panel FLEX BOOST feature is inactive if the heat ex changer protection is triggered When triggering signal for this fu...

Страница 13: ...tivated when air temperature exceeds 50 C and manual protection is activated when air temperature exceeds 100 C Automatic thermal protection 50 C is used to disconnect the electric heater if the tempe...

Страница 14: ...eter mining the moisture content of 70 1 a c t i v e o passive 10 ReturnWater 01h_Read_Coils 10 1 Return water temperature sensor alarm 1 a c t i v e o passive 11 ToutDoor 01h_Read_Coils 11 1 Outside...

Страница 15: ...power supply line is far from the unit the distance and voltage drop should be considered Device must be earthed Install the control panel at the designated place Install the supplied connection cable...

Страница 16: ...mper actuator Fire alarm input CO2 Extract air pressure Air quality transmitter Supply air pressure Transmitter 2 26 24V DC 27 intput 0 10V DC 28 GND P X16 9 T1 TV X16 8 24VDC 0 10VDC M6 G Y 0 0 GND Y...

Страница 17: ...LED2 Air damper close LED9 Medium fans speed LED2 LED3 Air damper open LED10 Minimal fans speed LED4 Water valve open LED11 Supply air fan speed reducing LED5 Water valve close LED12 Preheater LED6 B...

Страница 18: ...2 3 HIGH BOOST increase the flow of air I X32 4 COM COM X33 1 TIMER Stop DI X33 2 COM COM M5 Water cooler valve actuator X33 3 VAL Cooling valve opening PWM 24v 50hz AO X33 4 VAL Cooling valve closing...

Страница 19: ...re sensor AI X39 2 COM TE Exhaust air temperature sen sor X41 1 Exhaust air temperature sensor AI X41 2 COM PV Supply air fan X37 1 V1 Supply air fan 0 10V AO X37 2 COM COM IV Extract room s air fan X...

Страница 20: ...X33 25 X33 17 X33 12 X33 18 X33 14 X33 13 X35 1 X35 2 Y1 Control OPEN AC 24 V Y2 Control CLOSE AC 24 V G System potential AC 24 V 24VDC X16 1 2 1 3 X33 5 X33 4 X33 3 VAL VAL VAL Y1 Y2 24VAC 3 position...

Страница 21: ...N V1 COM X12 X42 X37 2 X37 1 COM V2 X37 3 X37 4 X4 X3 ModBus RTU RS485_2 RS485_2 A1 A1 A2 A2 A3 A3 TE TE X52 X33 19 X33 20 COM T WAT TJ X33 22 X33 21 X35 3 X35 4 X35 5 N L supply L control N N N EXT E...

Страница 22: ...8 9 X22 2 1 2 3 X29 1 3x1000W 230V KE1 A2 A1 PWM 0 TK TK RG2 Lin Lout 9 8 7 6 24VDC 24VDC X41 1 X41 2 X39 2 X39 1 X38 1 X38 2 X40 3 X40 2 X40 1 X34 8 X34 7 X34 6 X34 5 X34 4 X34 3 X34 2 X34 1 X33 26 X...

Страница 23: ...2 4 3 1 Q1 26 24V DC 27 intput 0 10V DC 28 GND Transmitter 2 24 VDC P 28 27 26 X33 22 X33 21 COM T set 16 15 X16 2 HR A4 A4 PUMP AC N L N V1 COM X12 X42 X37 2 X37 1 COM V2 X37 3 X37 4 X4 X3 ModBus RTU...

Страница 24: ...connector Q2 circuit breakers F1 fuse size 5x20 Color markings WH BK White Black RD Red GN BU Green Blue YE Yellow 5V TA COM RH RD WH YE GY RH U TA Jumper FA 7 2 1 X21 YE GN BU RD PWM STOP NO START NC...

Страница 25: ...fuse size 5x20 Air quality transmitter Supply air pressure Air quality transmitter CO2 Extract air pressure FA Jumper A2 A1 A2 A1 7 2 1 X21 YE GN BU RD PWM STOP NO START NC X33 15 X33 16 COM A 0 10 L...

Страница 26: ...connector Q2 circuit breakers F1 fuse size 5x20 Color markings WH BK White Black RD Red GN BU Green Blue YE Yellow 5V TA COM RH RD WH YE GY RH U TA Jumper FA 7 2 1 X21 YE GN BU RD PWM STOP NO START NC...

Страница 27: ...31 X16 7 24VDC 11 14 X16 3 7 8 R1 A1 A2 M4 1f 230V AC PE L N 3 1 P DX Cooling Jumper BOOST STOP NO START NC Transmitter 1 24 VDC 23 24V DC 24 intput 0 10V DC 25 GND Fan fall 1 2W max 1 2W max Fan run...

Страница 28: ...5 1 W5 2 TL 1 2 TE 1 2 U RH TA GN YE RD WH GND RH 5V TA DTJ100 X10 X8 X42 X12 A4 1 A4 2 COM V1 T OUT COM X41 1 X41 2 COM V2 X40 1 X40 2 X40 3 X38 1 X38 2 RG1 V2 5 01 3 2 Components and cables indicate...

Страница 29: ...3 position 24VAC DC Y1 open Y2 close G M5 M5 Jumper 24VDC 0 10VDC GND Transmitter 2 24VDC 0 10VDC GND Transmitter 1 FA NC NO COM TJ 1 2 24VDC 1 GND 2 open 3 close M1 M1 1 1 X16 2 1 2 2 1 3 2 1 4 2 1...

Страница 30: ...nkin apsauga TK32 09 100 C X22 ki tukinis lizdas Wago 769 112 K1 Kontaktorius AC1 kategorija 20A DRAWN BY CHECKED BY SIGNATURE DUTIES NAME DATE SALDA UAB Drawing Book CHECKED BY 3 4 4 5 6 7 7 EI A kle...

Страница 31: ...ue 0 75 White 0 5 Green yellow 0 75 Brown 0 75 DRAWN BY CHECKED BY SIGNATURE DUTIES NAME DA CHECKED BY 1 1 2 3 4 4 5 6 EI A klenikas EI D Aleksandravi ius Vent 224 1091 224 1091 0 1 0 PS Pricipal conn...

Страница 32: ...W5 2 TL 1 2 TE 1 2 U RH TA GN YE RD WH GND RH 5V TA DTJ100 X10 X8 X42 X12 A4 1 A4 2 COM V1 T OUT COM X41 1 X41 2 COM V2 X40 1 X40 2 X40 3 X38 1 X38 2 RG1 V2 5 01 3 2 Components and cables indicated in...

Страница 33: ...3 position 24VAC DC Y1 open Y2 close G M5 M5 Jumper 24VDC 0 10VDC GND Transmitter 2 24VDC 0 10VDC GND Transmitter 1 FA NC NO COM TJ 1 2 24VDC 1 GND 2 open 3 close M1 M1 1 1 X16 2 1 2 2 1 3 2 1 4 2 1...

Страница 34: ...sauga TK32 09 100 C X22 ki tukinis lizdas Wago 769 112 K1 Kontaktorius AC1 kategorija 20A EK2 A1 A2 EK3 A1 A2 DRAWN BY CHECKED BY SIGNATURE DUTIES NAME DATE SALDA UAB Drawing Book CHECKED BY 3 4 4 5 6...

Страница 35: ...0 75 White 0 5 Green yellow 0 75 Brown 0 75 DRAWN BY CHECKED BY SIGNATURE DUTIES NAME D CHECKED BY 1 1 2 3 4 4 5 6 EI A klenikas EI D Aleksandravi ius Vent 224 1091 224 1091 0 1 0 PS Pricipal connecti...

Страница 36: ...V1 T OUT COM X41 1 X41 2 COM V2 X40 1 X40 2 X40 3 X38 1 X38 2 RG1 V2 5 01 3 2 Components and cables indicated in dotted line should be connected by the manufacturer or by the user X37 X37 X52 X52 Cab...

Страница 37: ...2 3 position 24VAC DC Y1 open Y2 close G M5 M5 Jumper 24VDC 0 10VDC GND Transmitter 2 24VDC 0 10VDC GND Transmitter 1 FA NC NO COM TJ 1 2 24VDC 1 GND 2 open 3 close M1 M1 1 1 X16 2 1 2 2 1 3 2 1 4 2 1...

Страница 38: ...2 ki tukinis lizdas Wago 769 112 K1 Kontaktorius AC1 kategorija 20A RG3 A1 A2 PWM 0 TK TK EK1 A1 A2 EK2 A1 A2 EK3 A1 A2 DRAWN BY CHECKED BY SIGNATURE DUTIES NAME DATE SALDA UAB Drawing Book CHECKED BY...

Страница 39: ...te 0 5 Green yellow 0 75 Brown 0 75 DRAWN BY CHECKED BY SIGNATURE DUTIES NAME DA CHECKED BY 1 1 2 3 4 4 5 6 EI A klenikas EI D Aleksandravi ius Vent 224 1091 224 1091 0 1 0 PS Pricipal connection sche...

Страница 40: ...OUT COM X41 1 X41 2 COM V2 X40 1 X40 2 X40 3 X38 1 X38 2 RG1 V2 5 01 3 2 Components and cables indicated in dotted line should be connected by the manufacturer or by the user X37 X37 X52 X52 Cable is...

Страница 41: ...M2 3 position 24VAC DC Y1 open Y2 close G M5 M5 Jumper 24VDC 0 10VDC GND Transmitter 2 24VDC 0 10VDC GND Transmitter 1 FA NC NO COM TJ 1 2 24VDC 1 GND 2 open 3 close M1 M1 1 1 X16 2 1 2 2 1 3 2 1 4 2...

Страница 42: ...S NAME DATE SALDA UAB Drawing Book CHECKED BY 1 1 2 3 4 4 5 6 7 7 EI A klenikas EI D Aleksandravi ius Pyn l PR 221 1284 221 1284 0 1 0 PS Pricipal connection scheme 1 01 2017 10 19 2017 10 19 2017 10...

Страница 43: ...Green yellow 0 75 Brown 0 75 T1 1 4 TV 1 2 DRAWN BY CHECKED BY SIGNATURE DUTIES NAME DA CHECKED BY 1 1 2 3 4 4 5 6 EI A klenikas EI D Aleksandravi ius Vent 224 1091 224 1091 0 1 0 PS Pricipal connecti...

Страница 44: ...Average kWh a 4410 4410 4410 4410 AHS Cold kWh a 8628 8628 8628 8628 AHS Warm kWh a 1994 1994 1994 1994 ErP Compliance 2018 2018 2018 2018 Internet address for disassembly instructions www salda lt R...

Страница 45: ...EN 45 RIS 400 700 P EKO 3 0 v2019 06 AHS Warm kWh a 1990 1990 1990 1990 ErP Compliance 2018 2018 2018 2018 Internet address for disassembly instructions www salda lt...

Страница 46: ...reduction LST EN 60204 1 2006 Safety of machinery Electrical equipment of machines Part 1 General requirements LST EN 60335 1 2012 Household and similar electrical appliances Safety Part 1 General re...

Страница 47: ...ver the equipment to manufacturer Delivery costs should be covered by customer Manufacturer reserves the right to change this technical passport any time without prior notice if some typographic error...

Страница 48: ...NANCE TABLE Product name LOT number Instalation Interval Datum Fan cleaning Once a year Heat exchanger cleaning Once a year Filter replacement Every 3 4 months Look at the product label At least NOTE...

Отзывы: