6.4. FILTERS
,QRUGHUWRUHPRYHWKH¿OWHUVRSHQXQLWGRRUDQGWDNHRႇWKH¿OWHUV
'LUWLQFUHDVHVDLUUHVLVWDQFHLQWKH¿OWHUWKHUHIRUHORZHUDPRXQWRIDLULVVXSSOLHGLQWRWKHSUHPLVHV$UURZVRQWKH¿OWHUVPXVWFRPSO\ZLWKDLUÀRZ
direction.
$IWHUFKDQJLQJWKH¿OWHUVSOHDVHUHORDGWKH¿OWHUWLPHU7KHLQVWUXFWLRQRQUHORDGLQJFDQEHIRXQGLQWKHFRQWUROSDQHORSHUD
-
tion manual or on our website www.salda.lt
2SHUDWLRQRIWKHXQLWZLWKRXW¿OWHUVLVQRWDOORZHG
&KDQJHWKH¿OWHUVHYHU\PRQWKVRUDFFRUGLQJWRWKHQRWL¿FDWLRQRQWKHFRQWUROGHYLFH
6.5. ROTOR
MAINTENANCE
• Maintenance of rotor heat exchanger must be performed on annual basis, once per year.
•
(QVXUHWKHJDSVRIKHDWH[FKDQJHUDUHFOHDQWKHEUXVKHVDUHQRWZRUQWKHEHOWGULYHLVQRWZRUQDQGWKHFODPSLQJQRGHVRIWKHURWRUKHDW
exchanger are tight.
•
5RWRUKHDWH[FKDQJHUFDQEHHDVLO\UHPRYHGIURPWKHXQLW'LVFRQQHFWWKHSRZHUFRUGRIWKHPRWRURIKHDWH[FKDQJHUUHOHDVHDQGUDLVHWKH
clamp of the rotor heat exchanger section, and then remove the heat exchanger.
•
+HDWH[FKDQJHUPXVWEHFOHDQHGXVLQJWKHVROXWLRQRIZDUPZDWHUDQGQRQFRUURVLYHWRZDUGDOXPLQLXPDONDOLQHDJHQWRUDQDLUVWUHDP$SSO\LQJ
direct stream of liquid is not recommended, because this can cause damage to the device.
•
:KLOHFOHDQLQJPDNHVXUHWKDWQRPRLVWXUHDQGOLTXLGZLOOHQWHULQWRWKHPRWRURIWKHKHDWH[FKDQJHU
•
+DYLQJUHLQVWDOOHGWKHKHDWH[FKDQJHUIDVWHQLWVVHFWLRQZLWKWKHFODPS&RQQHFWWKHKHDWH[FKDQJHUPRWRU
&$87,21KHDWH[FKDQJHUFDQQRWEHXVHGZKHQWKH¿OWHUVDUHUHPRYHG
6.6. FANS
MAINTENANCE
•
)DQPDLQWHQDQFHVKRXOGEHSHUIRUPHGE\H[SHULHQFHGDQGWUDLQHGVWDႇRQO\
• The fan should be inspected and cleaned at least once per year.
•
3ULRUWRFRPPHQFLQJDQ\PDLQWHQDQFHRUUHSDLUVPDNHVXUHWKHIDQLVGLVFRQQHFWHGIURPWKHSRZHUVRXUFH
• Proceed to maintenance and repair after any fan rotation is stopped.
•
2EVHUYHVWDႇVDIHW\UHJXODWLRQVGXULQJPDLQWHQDQFHDQGUHSDLUV
• The motor features a heavy-duty ball bearing design. The motor is completely sealed and grease- free.
• Detach the fan from the unit.
• The impeller should be particularly checked for built-up material or debris that may cause an imbalance. Excessive imbalance may lead to ac-
FHOHUDWHGZHDURQPRWRUEHDULQJVDQGYLEUDWLRQ
•
&OHDQLPSHOOHUDQGLQVLGHKRXVLQJZLWKPLOGGHWHUJHQWZDWHUDQGGDPSVRIWFORWK
• Do not use high-pressure cleaner, abrasives, sharp tools or caustic solvents that may scratch or damage the housing and impeller.