background image

AVS S / SVS / SVS V v2022.1

EN |

 3

2.  SYMBOLS AND MARKING

Warning – pay attention

Additional information

Apply the auxiliary label on the unit (on an easily accessible location) or on the dashed location of the technical manual in order to keep the im-

portant information about the unit.

Figure. 2.1.  Technical label

1 - Logo; 2 - Product code (SKU); 3 - Product name; 4 - Technical data; 5 - Lot number; 6 - Production place.

Содержание AVS S

Страница 1: ...AVS S SVS SVS V EN OPERATION INSTALLATION MAINTENANCE INSTRUCTIONS...

Страница 2: ...ATION ABOUT THE PRODUCT 5 4 1 DESCRIPTION 5 4 2 DIMENSIONS AND WEIGHT 5 5 INSTALLATION 7 5 1 RECEPTION OF GOODS 7 5 2 TRANSPORTATION AND STORAGE 7 5 3 UNPACKING 7 5 4 MOUNTING 7 6 MAINTENANCE 9 7 INSP...

Страница 3: ...Apply the auxiliary label on the unit on an easily accessible location or on the dashed location of the technical manual in order to keep the im portant information about the unit Figure 2 1 Technical...

Страница 4: ...e manufacturer Main safety rules Warnings Do not use the unit for purposes other than its intended use Do not disassemble or modify the unit in any way Never use this unit in any explosive or aggressi...

Страница 5: ...h the cover removed the heater can be cleaned and inspected Easy to mount Suitable for operation indoor environment The purpose of the unit is heating of clean air The unit is used in clean air ventil...

Страница 6: ...0 2 500x300 4 600x300 2 600x300 4 L mm 300 W mm 440 540 640 H mm 240 290 340 G mm 400 500 600 D mm 200 250 300 din 3 4 dout 3 4 A1 mm 420 520 620 A2 mm 220 270 320 Weight kg 8 10 5 10 13 5 13 16 14 18...

Страница 7: ...the unit please check if all ordered equipment have been delivered Any variation from the ordered equipment list must be reported to the product supplier 5 4 MOUNTING Installing should only be perform...

Страница 8: ...AVS S SVS SVS V v2022 1 8 EN b c d a e Figure 5 4 3 S3...

Страница 9: ...rculation Temporary increase water temperature for this Check tightness of water supply system Cleaning Disconnect and remove heater If heater is soiled use vacuum cleaner or airflow blast In case of...

Страница 10: ...ion of the ventilation unit the inspection of the entire ventilation system i e inspect if the air collection grating or the units for the air supply to the room are not contaminated must be carried o...

Страница 11: ...uipment Directive 2014 68 EU The following harmonized standards are applied in applicable parts LST EN ISO 12100 2011 Safety of machinery General principles for design Risk assessment and risk reducti...

Страница 12: ...the equipment to manufacturer Delivery costs should be covered by customer Manufacturer reserves the right to change this technical passport any time without prior notice if some typographic errors o...

Страница 13: ...13 AVS S SVS SVS V v2022 1...

Страница 14: ...14 AVS S SVS SVS V v2022 1...

Страница 15: ...15 AVS S SVS SVS V v2022 1...

Страница 16: ...OTE The customer shall be required to complete the Product Maintenance Table MANUALS IN OTHER LANGUAGES DE FR IT LT RU https select salda lt file avs svs svsv de https select salda lt file avs svs svs...

Отзывы: