Salamander Pumps CombiBoost Скачать руководство пользователя страница 10

8

• EN 60335-1:2002 and EN 60335-2-41:2003 Household and similar electrical appliances – 

safety (Part 1 General requirements and Part 2-41 Particular requirements for pumps). 
The company operates a policy of continuous development and reserves the right to change 

any of the specifications of its products without prior notice. All information data and 

illustrations given in this leaflet may be subject to variation.

Safety in operation

These appliances are not intended for use by persons (including children) with reduced 

physical, sensory or mental capabilities, or lack of experience and knowledge, unless they 

have been given supervision or instruction concerning use of the appliance by a person 

responsible for their safety. Children should be supervised to ensure that they do not play 

with the appliance. 

WEE Directive

Your appliance contains valuable materials which could be recovered or recycled. At the end 

of the product’s useful life please dispose of it at an appropriate civil waste collection point.

WEEE Directive 2012/19/EU

At the end of the product life dispose of 

packaging and product in a corresponding 

recycling centre. 
Do not dispose of the unit with the usual 

domestic refuse. Do not burn the product.

Содержание CombiBoost

Страница 1: ...Pump installation and warranty guide for CombiBoost ISSUE 1 NOVEMBER 2019...

Страница 2: ...r safe operation and a trouble free system It is therefore important to read these instructions thoroughly and ensure that you comply with them Incorrect fitting will invalidate the warranty If your i...

Страница 3: ...stallation checklist 2 Application notes 3 4 Typical installations 5 Commissioning 6 General specifications 7 8 Troubleshooting 9 Fittings kit 10 PumpWise and warranty 11 To the installer 12 Terms and...

Страница 4: ...tion Don ts Never fit to hot water piping Never fit the pump to communal risers Never pump directly from or to another pump only one CombiBoost may be installed per household supply Never fit to flexi...

Страница 5: ...coming water flow under low pressure conditions It cannot overcome restricted incoming pipework and replacement water pipes should be installed in this scenario Installation must comply with the relev...

Страница 6: ...ctrical requirements The CombiBoost must be connected to the electrical supply using the mains cable with the attached plug This plug must be connected to an accessible socket that has been installed...

Страница 7: ...ting Ball valve Isolation valve for combi boiler Figure 4 Modified pipe work for clearance Pipe centre to wall 37mm 1 Combi boiler 2 Combi boiler Figure 5 Typical installation locations NOTE Refer to...

Страница 8: ...ischarged from the connecting pipe work and pump chamber The best method is 1 Connect pump pipe work 2 Check that all isolating valves are open 3 Turn mains water on at the stop tap 4 Ensure all air i...

Страница 9: ...ustomers with even quieter centrifugal pumps However no pump is completely silent and this type of pump is characterised by a high pitched hum or whine Mechanical seals Scale deposits in water supplie...

Страница 10: ...h reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for...

Страница 11: ...ter Ensure that inlet filter is free from debris Air in system Run system on full cold for a whole house install or full hot in a combi boiler install with pump switched off i e mains water supply onl...

Страница 12: ...ctions 1 x Ball valve Tap connector x 22mm compression 1 x tap connector Tap connector x 22mm compression 2 x reducer 22mm x 15mm compression reducer WHOLE HOUSE COMBI ONLY Isolating ball valve Tap co...

Страница 13: ...tory one year warranty Our PumpWise commitment Our PumpWise helpline is here to help you and we aim to provide a support service second to none Installers and consumers can be sure of a speedy respons...

Страница 14: ...formed in any way without the consent in writing of the Company or if any component or accessory shall have been replaced by a type not specified by the Company or if the equipment is incorrectly inst...

Страница 15: ...pany s manufacture one year from date of purchase c The warranty period in respect of any product repaired or replaced under the warranty shall be part of the above period s which remain unexpired d I...

Страница 16: ...er your warranty Apply online at www salamanderpumps co uk Apply by phone 0191 516 2002 Unit 2c Colima Avenue Enterprise Park West Sunderland SR5 3XE Get in touch we re here to help call us on 0191 51...

Отзывы: