89
6
变频器运行后 电机不转
动
Motor not running after
frequency converter
running
电机线没接好;
Not connect motor wire well;
变频器参数设置错误(电机参数);
Error
frequency converter parameter setting (motor
parameter);
驱动板与控制板连线接触不良;
Bad contact
between drive board and control board wire;
驱动板故障;
Drive board failure;
重新确认变频器与电机之间连 线;
Confirm the wire between frequency
converter and motor;
更换电机或清除机械故障;
Renewal
motor or solve the mechanical failure;
检查并重新设置电机参数;
Check and
reset motor parameters;
7
变频器频繁报 过流和过
压 故
障
Frequency
converter
frequently
report over current and
over voltage failure
电机参数设置不对;
Incorrect motor
parameter setting;
加减速时间不合适;
Unsuitable accelerate
and moderate time;
负载波动;
Load wave;
重新设置电机参数或者进行电 机调
谐;
Reset motor parameter or process
motor tune;
设置合适的加减速时间;
Set suitable
accelerate and moderate time;
寻求厂家服务;
Seeking factory service
8
上电显示
Power on
indication
控制板上相关器件坏;
The relate apparatus
on control board damaged;
更换控制板;
Renewal control board;