background image

 

Fig. 3.1 Fix the hanging panel

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fig. 3.2 Install the inverter on hanging panel

 

   

 

 

 

 

 

 

 

 

 

 
             

 

Fig. 3.3 Fix the inverter and hanging panel                                     

 

4

Power grid side electrical connection

 

Type

 

Cross-sectional area of cables

mm²

 

Scope 

Recommended value 

R6-15K/17K/20K/22K/25K-T2-32, R6-

5K/6K/8K/10K/15K-T2-32-LV, R6-25K-T2-32-B 

10.0-16.0 

16.0 

R6-30K/33K/36K-T3-32, R6-20K-T3-32-LV, R6-

25K/30K-T3-32-B 

16.0-35.0 

25.0 

R6-36~50K-T4-32, R6-25K/30K-T4-32-LV 

16.0-35.0 

25.0 

Table 4.1 AC side electrical connection 

AC side electrical connection 

                             

                 

 

 

 

 

 

 

 

                          Fig. 4.1 Inverter ground protection                                                          Fig 4.2 Thread the cable into the quick connector                                   

 

5

DC side connection 

Cross-sectional area of cables(mm²

)

 

Outside diameter of the cables (mm)

 

Scope

 

Recommended value

 

4.0-6.0 

4.0 

4.2-5.3 

Table 5.1 Recommended specifications of DC cables 

 

 
                         

         

 
     

 

 

 
                     

Fig. 5.1 Connect DC cable in a crimp-type way 

       

                    Fig. 5.2 Insert the joint and screw it up     

             

Fig. 5.3 Connect to the inverter

 

6

Connect the communication modules

 

 

 

 

 

 

 

 

 

 

 

 

 

Fig. 6.1 Connect the communication modules

 