PDS33 Series
- 30 -
4.4 User Definable Parameters
○:
The parameters can be modified at stop or running status.
●:
The parameters cannot be modified at running status.
◎ :
The parameters which are actual-detecting record value and cannot be
modified.
Function
Code
Function
Description
Unit
Factory
setting
Modification
Type
Communicati
on Address
F0 Group
:
Basic Function
F0.01
Start/stop
signal option
0
:
Keypad
(
LED off
)
1
:
Terminal
(
LED on
)
2
:
RS485
Communication
(
LED
Flickering
)
1
0
●
F001
F0.03
Main
frequency
source
1
:
F0.08
(
Knob and
UP/DOWN available
)
2
:
AI1
3
:
AI2
8
:
MPPT
9
:
Communication
1
8
○
F003
F0.08
Keypad set
frequency
0.00Hz
~
Max F0.10
0.01Hz 50.00Hz
○
F008
F0.09
Running
direction
0
:
FWD
1
:
REV
1
0
○
F009
F0.10
Max output
frequency
50.00Hz
~
320.00Hz
0.01Hz 50.00Hz
●
F00A
F0.12
Up limit
frequency
F0.14
~
F0.10
0.01Hz 50.00Hz
○
F00C
F0.14
Low limit
frequency
0.00Hz
~
F0.12
0.01Hz 0.00Hz
○
F00E
F0.15
Use of low
limit frequency
When set frequency is
lower than low limit
frequency,
0
:
Run at low limit
frequency
1
:
Stop
2
:
Run at 0.00Hz
1
0
○
F00F
F0.16
Carrier
0.5kHz
~
16.0kHz
0.1kHz Due to
○
F010