N
OTE
:
It's not necessary to ignite
all the plugs in a dual plug cylin-
der (two glow plugs per cylinder)
of Saito engines. It's only neces-
sary to apply heat to the rear
plugs; the front plugs will ignite
once the engine reaches operating
temperature.
N
OTE
:
A very common error is to
remove the glow plug igniter (or
on-board glow driver) too early.
It's suggested that the igniter be
left attached (or left on in the case
of an on-board glow driver) until
the engine has been run up and
the high-speed needle valve has
been properly adjusted.
15. Using either a "start stick" or
electric starter, spin the propeller
until the engine is running.
N
OTE
:
When using an electric
starter, care should be taken to be
sure that the engine does not
become "hydro-locked." While
the electric starter will turn the
engine over, it may damage the
connecting rod or other compo-
nents. If the engine becomes
hydro-locked, simply remove the
glow plugs and turn the engine
over a few times with the chicken
stick or electric starter. The excess
fuel will be forced to exit the
engine via the cylinder heads.
16. Initial break-in:
After the engine starts, open the
high speed needle valve slightly.
Do not
exceed 4,000 rpm for the
first ten (10) minutes of operation.
This allows all parts to mate prop-
erly with good lubrication.
N
OTE
:
Due to the excessively
"rich" mixture setting, it may be
necessary to leave the heat source
attached (or left on) to the glow
plugs.
Subsequent runs may be made
while slightly leaning out the mix-
ture with each tank of fuel.
Generally, 40 minutes is consid-
ered sufficient for normal break-in
prior to the first flight.
N
OTE
:
FA-90R3 rotary units and
slide ways of the engine have
been lubricated at assembly with
black molybdenum oil to prevent
wearing or seizure. Hence, black
exhaust oil comes out of the
breather nipple and muffler at
break-in operation. This discharge
is not a sign of trouble and you
can continue flying.
9
校了_斎藤製作所_MCFSE冊子cs3.indd 9
2010/11/04 10:01:48
Содержание FA-90R3
Страница 1: ...INSTRUCTION MANUAL Multi Cylinder Four Stroke Engines FA 90R3 FA 170R3 FA 325R5 D FA 200R3 FA 450R3 D...
Страница 20: ...PARTS LIST FA 90R3 18...
Страница 21: ...PARTS LIST FA 170R3 FA 200R3 19...
Страница 22: ...FA 325R5 D PARTS LIST 20...
Страница 23: ...PARTS LIST FA 450R3 D 21...
Страница 28: ...Exclusively Distributed by Horizon Hobby Inc Champaign IL 61822 Copyright Sep 2010 Stock SAIMAN3 C...