3.8 Overload protection
The CDM354 motor is equipped with 2 LEDs. When the motor is used overloaded, the
orange LED lights up to warn the operator that the motor is overloaded. The operator must
immediately lower the load.
If the red LED lights up the motor stops immediately. Before restarting the engine, a general
inspection must be carried out.
The CDM354 motor is also equipped with 4 power level lamps. The operator can adjust the
pressure applied depending on the number of lit LEDs.
1 or 2 LEDs on, the charge is correct.
3 or 4 LEDs on, load is high.
The CDM354 is also equipped with an LCD screen, it indicates in real time the amperage,
the voltage, the internal temperature, the power and the number of hours of use.
It also indicates ALARM when the motor is overloaded.
3.9 Statement regarding vibration emissions
Declared vibration emission value according to
EN 12096.
Machine
Emission measured value
vibration am/s
2
Uncertainty K
Model
m/s
2
4.2
1.5
CDM354
•
Values determined according to the procedure described in standard
EN 60745-1; EN
55014; EN 61000
•
The measurements are made with new machines. Actual values on site may vary with
operating conditions, depending on:
Materials worked
Machine wear
Lack of maintenance
Tool not appropriate for the application
Tool in poor condition
Non-specialized operator
Etc…
•
The time of exposure to vibrations is also a function of work performance (linked to the
adequacy of machine / tool / material worked / operator)