Sailor HC4500 Скачать руководство пользователя страница 18

14

Using Two  Control  Units

You can connect two control units to the system. However, it can
only be controlled by one control unit at a time.

Priority of Control Unit #1

Control unit #1 has the highest priority, i.e. you can always control
the system by means of control unit #1 – even if control unit #2 has
initiated a distress call.

Control Unit #2 Taking Over the Control

When control unit #1 is in the DSC Status Menu, control unit #2 can
take over the control of the system by leaving the DSC Status Menu.
When control unit #2 returns to the DSC Status Menu, the control is
automatically given back to control unit #1.

Status Indication

Control Unit #1:
When control unit #2 controls the system, the display of control unit
#1 shows what activity is taking place. The following read-outs may
appear:

OCC by unit 2 sending Distress alert” means that control

unit #2 is transmitting a distress call, or awaiting automatic
retransmission.

OCC by unit 2 sending DSC call” means that control unit #2

is transmitting an ordinary DSC call.

OCC by unit 2 using DSC functions” means that control unit

#2 is in a DSC menu without transmitting a call.

OCC by unit 2 using Radio functions” means that control

unit #2 is not in a DSC menu.

Control Unit #2:
The display of control unit #2 always shows when the system is
busy. When the system is not busy, the display shows the DSC
Status Menu.
If control unit #2 tries to take over the control, but is not allowed to do
so, this is indicated by both a sound and the display read-out  “

OCC

by unit 1”.

Responding to Incoming DSC Calls

When a call comes in, only the active control unit – i.e. the one that
controls the system at the moment – is to respond.

If for instance control unit #2 has sent an individual DSC call, control
unit #2 is to receive and respond to the acknowledgement call that
may follow.
If a call comes in when both control units are in the DSC Status
Menu, and therefore not active, both control units are to receive and
respond to the call.

Power On/Off By Control Unit #2

Power On
You can turn on the whole system by means of control unit #2. If the
display shows the words “

Unit switched off”, and the on/off button is

pressed,  what happens depends on whether or not control unit #1 is
controlling the system at the moment:

a) If control unit #1 is controlling the system, this will be

indicated by the display of control unit #2.

b) If control unit #1 is not controlling the system,  control unit #2

will start up in the DSC Status Menu.

When the whole system is off, it makes no difference which control
unit turns it on.

Power Off
You cannot turn off the whole system by means of control unit #2.
When you press the on/off button, only  control unit #2 is turned off.
The display will then show the words “

Unit switched off”.

Interconnecting

When you have received a DSC call, including working frequency, it
is possible to transfer the system control from control unit #1 to
control unit #2. To do so, in the Frequency menu, key: “

Shift” + “INT-

C/InterCom”.
When a DSC call is transferred from control unit #1 to control unit #2,
the right working frequencies are maintained.
If the handset of control unit #2 is not lifted within five minutes, the
control automatically returns to control unit #1.

DSC Scanning Frequencies

You cannot change the DSC scanning frequencies by means of
control unit #2. The scanning frequencies used when in the DSC
Status Menu of control unit #2 are the same as if in the DSC Status
Menu of control unit #1.
If control unit #1 changes the DSC scanning frequencies, that
information is passed on to control unit #2. Therefore, if control unit
#2 is given the control, and starts scanning, the same scanning
frequencies are used.

Содержание HC4500

Страница 1: ...SAILOR HC4500 MF HF CONTROL UNIT Operating Instructions Distress Calls see page ii List of contents see page 1...

Страница 2: ...fault on the distress frequency 2187 5 kHz Wait for answer The distress call is auto repeated every 5 minutes on the same distress frequency DISTRESS Acknowledgement 4 Press VIEW to read the contents...

Страница 3: ...s guided by the text displayed 6 Tuning control 7 ON OFF push button 8 Volume control 9 TEL DSC function switch In TEL mode radiotelephone parameters are shown and selected In DSC mode DSC parameters...

Страница 4: ...or the daily user of the system Additionally it includes a section on the installation procedures and on page ii standard distress procedures We highly recommend you to read the manual before you star...

Страница 5: ...tching ON OFF 3 Setting Backlight Level 3 Switching Loudspeaker ON OFF 3 Volume Control 3 Switching Squelch ON OFF 3 Setting Transmitter Power Level 3 Manual Call Functions 4 Telephony Channel Display...

Страница 6: ...for public correspondence with coast stations are arranged in pairs for duplex semi duplex operation For the HF bands these channels are allocated numbers by ITU on an international basis In addition...

Страница 7: ...ON OFF 1 Press the Shift key followed by the SPK key Volume Control 1 Rotate the VOL button to adjust the loudspeaker sound volume Switching Squelch ON OFF SSB Telephony mode 1 Press the Shift key fol...

Страница 8: ...frequencies Switches to Station display for selection of another station Steps to the next lower channel number of the station Steps to the next higher channel number of the station Squelch setting R...

Страница 9: ...ANCEL NAME LYNGBY CALL SIGN OXZ MMSI NO 002191000 TELEX NO 37383 STN STATIONTABLE CH FREQ MODE AM TELEPHONY SIGNAL BAND POWER HIGH SQUELCH OFF DISTRESS Rx Tx 2182 0 kHz The frequencies for distress an...

Страница 10: ...traffic lists are transmitted in more frequency bands simultaneously search for the channel with the best propagation conditions Making a Manual Call Wait until transmission of the traffic list has f...

Страница 11: ...distress frequencies and one for watch on the public DSC frequen cies calling watch The calling watch receiver is identical with the receiver of the radio and therefore it is possible to switch the c...

Страница 12: ...cies Changes distress frequency used default for quick distress calls Specified frequency List of watch frequencies EXIT Calling Watch 02 02 01 01 04 Rx Freq 02187 5kHz DSC STATUS display DSC STATUS C...

Страница 13: ...part of call CALL CONTENT Time 10 55 00 13 Okt 97 TYPE Individual FROM 219000012 CAT Routine ACKN Request MORE Press CONNECT to transmit and set channel Press CHANGE to change the acknowledgement Sele...

Страница 14: ...08 55 00 22 Sep 97 TYPE Distress FROM 219001000 MSG Fire Received on 2187 5 kHz MORE If the ship in distress is within a reachable distance press 2182 and listen to the subsequent information Press A...

Страница 15: ...cy is included in the call and this frequency is used as working frequency for the following radio communication Accept the number A sub menu where a pre programmed ship can be selected Key in the shi...

Страница 16: ...ect the frequency on which the call is transmit ted Select ACCEPT to make a call directly to the shore station and talk with a person there if no phone number is keyed in Select TEST CALL to make a te...

Страница 17: ...e first screen on the same subject Select ADD to make a new call ADD DELETE CANCEL AGAIN Accepts the data Go to the next screen on the same subject Lower left side of the display is the data area Righ...

Страница 18: ...all control unit 2 is to receive and respond to the acknowledgement call that may follow If a call comes in when both control units are in the DSC Status Menu and therefore not active both control uni...

Страница 19: ...ntered manually if not obtained from e g a GPS SSB telephony AM telehony FEC EXTENDED See next page Advanced DSC Calls Extended DSC calls make it possible for you to control the call completely within...

Страница 20: ...TY TAPE MORSE SHIP POSITION No info The data in the example gives the area N 55 57 W 6 9 ROUTINE URGENCY DISTRESS SAFETY BUSINESS DATA V21 V22 V22 BIS V23 V26 V26 BIS V26 TER V28 TER V32 Unable to com...

Страница 21: ...es of how to use the function tree An example Changing the Display Contrast Press SHIFT and FUNC to enter function menu Select function or group of settings USER TELEPHONY DSC MORE Select the USER fun...

Страница 22: ...View View ch Protection Read Transceiver protection codes Test Self test TU module Menu Submenu Level 1 Submenu Level 2 Parameters DSC MMSI The MMSI number of the unit ACKN Auto ackn on request On Of...

Страница 23: ...ages to several stations simultaneously A special class of FEC allows selective calling by means of call codes The message is transmit ted in inverted format and only receiving stations with the corre...

Страница 24: ...ll code expecting the call code of the station to be called to be typed Upon carriage return Enter the ARQ transmis sion begins Edit Mesg F4 Edits a message to be transmitted later Send Mesg F5 Transm...

Страница 25: ...s been established or in the case of FEC until the opening phase sequence has been transmitted When the system is ready for message transmission a is printed and the Tx keyboard indicator shines stead...

Страница 26: ...er on When light comes on in the indicator lamps release the LF button The printer version is now printed followed by a test print out The version must be F W 01 01 S33 67 7145 Keyboard The keyboard i...

Страница 27: ...he terminal is ready to receive Example of ARQ Transmission to a Coast Station When the GMDSS telex terminal is on indicated by the Standby keyboard indicator lamp and the radio is set up to the desir...

Страница 28: ...text memory Having completed the transmission the answer back code of the subscriber is requested by pressing the WRU key x 54321 ZYXW and own answer back is sent by pressing the DE key 123456789 abc...

Страница 29: ......

Страница 30: ......

Страница 31: ......

Страница 32: ......

Отзывы: