27
BBQ Specifications
Burner 4
Burner
Injector
Size
0.039"
Gas/Pressure
11" per W.C
Input Rate (main)
11,700 BTU/HR*1 (Orifice size: 1.0 MM)
Standard
ANSI STD Z21.58-2018 Outdoor Cooking Gas Appliances
TECHNICAL AND SERVICING INFORMATION
This appliance is designed for outdoor use only using Propane gas at a supply pressure of 11" per WC
and must be serviced by a competent person in accordance with the instructions included. Please read all
accompanying documentation carefully.
TROUBLESHOOTING
Problem
Possible
Cause
Solution
Burner will not light using
LP gas cylinder is empty
Replace with full cylinder
the ignition system
Faulty
regulator
Have
regulator
checked
or
replace
Obstructions in burner
Clean burner
Obstructions in gas jets or gas hose Clean jets and gas hose
Electrode wire is loose
Reconnect wire
Electrode or wire is damaged
Change electrode and wire
Low flame or flashback
Obstructions in burner
Clean burner
(fire in burner tube - a
hissing or roaring noise may
be heard
Obstructions in gas jets or
Clean jets and gas hose
gas
hose
Windy conditions
Use grill in a more
sheltered
position
Gas valve knob difficult to Gas valve jammed
Replace gas valve
turn