Страница 1: ...Halfpar 24x3W RGB FC SG HALFPAR24 MANUALE UTENTE USER MANUAL All manuals and user guides at all guides com a l l g u i d e s c o m ...

Страница 2: ...NSIONE p 7 5 ISTRUZIONI PER L USO p 9 6 MANUTENZIONE p 11 7 SPECIFICHE TECNICHE p 11 INDEX 1 INTRODUCTION p 12 2 SAFETY INSTRUCTIONS p 13 3 OPENING AND CONTROL p 15 4 INSTALLATION AND SWITCH ON p 16 5 SETUP p 18 6 MAINTENANCE p 20 7 TECHNICAL SPECIFICATIONS p 20 Rev 01 01 15 All manuals and user guides at all guides com ...

Страница 3: ...era responsabile per favorire il riutilizzo sostenibile delle risorse materiali Gli utenti domestici sono invitati a contattare il rivenditore presso il quale è stato acquistato il prodotto o l ufficio locale preposto per tutte le informazioni relative alla raccolta differenziata e al riciclaggio per questo tipo di prodotto Gli utenti aziendali sono invitati a contattare il proprio fornitore e ver...

Страница 4: ...dotto Il cavo di sicurezza deve essere debitamente agganciato al dispositivo e fissato alla struttura di sostegno in modo che in caso di cedimento del sistema di supporto primario si abbia la minore caduta possibile del dispositivo Se il cavo di sicurezza si usura deve essere sostituito con un ricambio originale DISTANZA MINIMA DEGLI OGGETTI ILLUMINATI Il proiettore deve essere posizionato in modo...

Страница 5: ...orbita a cui è necessario fare riferimento per valutare il numero massimo di dispositivi da collegare alla linea elettrica al fine di evitare sovraccarichi Se il cavo di alimentazione esterno di questa apparecchiatura da illuminazione è danneggiato deve essere sostituito con un cavo speciale disponibile esclusivamente presso i rivenditori PROEL Non attivare mai l apparecchiatura con lenti e o cope...

Страница 6: ...stato esposto a drastici sbalzi di temperatura lasciare spenta l unità finché non raggiunge la temperatura ambiente in quanto la presenza di condensa potrebbe danneggiare il prodotto se acceso Controllare che la scatola contenga i seguenti articoli N 1 SG HALFPAR24 N 2 Staffe di supporto N 1 Cavo di alimentazione N 1 Manuale Utente VISTA ANTERIORE 1 Manopola fissaggio staffa 2 Lente 3 Staffa di su...

Страница 7: ...lata a pavimento in appoggio sugli appositi piedini in gomma a parete a soffitto o su truss ATTENZIONE E OBBLIGATORIO il montaggio della fune di sicurezza PLH200 venduta separatamente nel caso in cui il prodotto sia appeso a parete a soffitto o su truss Ad eccezione di quando il dispositivo è appoggiato a pavimento il montaggio del cavo di sicurezza è obbligatorio All manuals and user guides at al...

Страница 8: ... nella targhetta dei dati elettrici 4 3 COLLEGAMENTO ALLA CATENA DMX Utilizzare un cavo conforme alle specifiche EIA RS 485 bipolare intrecciato schermato 120Ohm di impedenza caratteristica e bassa capacità PROEL DMXD DMXD1 Non utilizzare cavo microfonico o altro cavo con caratteristiche diverse da quelle specificate Le terminazioni devono essere effettuate con connettori maschio femmina tipo XLR ...

Страница 9: ...ale blue SP 01 SP 99 Regolazione velocità strobo SLAV SLA Modalità Slave 5 2 MODALITA MASTER SLAVE In questa modalità possono essere collegate più unità insieme come un unica catena e funzionare in modo sincronizzato Utilizzare un cavo DMX per collegare insieme tutte le unità dal connettore DMX OUT a DMX IN Definire la prima unità della catena come Master tutte le altre unità devono essere imposta...

Страница 10: ...per i canali 2 3 e 4 Modalità 7 canali Canale Valore Funzione 1 000 255 Master Dimmer 2 000 255 Rosso 3 000 255 Verde 4 000 255 Blu 5 000 024 Non usato 025 049 Esecuzione completa di tutti i programmi 050 074 Esecuzione programma 2 075 099 Esecuzione programma 3 100 124 Esecuzione programma 4 125 149 Esecuzione programma 5 150 174 Esecuzione programma 6 175 199 Esecuzione programma 7 200 255 Modal...

Страница 11: ...ltra parte eventualmente danneggiata devono essere sostituite con ricambi originali 7 SPECIFICHE TECNICHE Alimentazione 100 240V 50 60HZ LED 24x3W RGB 3 in 1 Angolo del fascio di luce 25 Potenza assorbita 82W Modalità operative Auto Sound active Master slave DMX512 Regolazione elettronica della luminosità 0 100 DMX 3 6 7 canali Display digitale per impostazione indirizzo e funzioni Ingresso e usci...

Страница 12: ...of wastes and recycle it responsibly to promote the sustainable reuse of material resources Home users are encouraged to contact the retailer where they purchased this product or their local government office for details on separate collection and recycling this type of product Business users are encouraged to contact their supplier and check the terms and conditions of the purchase contract This ...

Страница 13: ...ety cable must be properly attached to the device and fixed to the supporting structure so that in case of failure of the primary supporting system it has the lowest possible fall of the device If the safety cable wear must be replaced with an original spare MINIMUM DISTANCE OF ILLUMINATED OBJECTS The projector must be positioned so that the objects hit by the beam of light are at least 1 meter fr...

Страница 14: ...ry to refer to evaluate the maximum number of devices to be connected to the electricity line in order to avoid power overloading If the external power cord of this light is damaged it must be replaced with a special cord exclusively available from Your PROEL dealer Never operate the equipment with lenses and or covers missing or damaged In case of non use it is recommended to unplug the projector...

Страница 15: ...ARNING If the product has been exposed to drastic temperature changes let the unit turned off until it reaches room temperature because the presence of condensation can damage the product if it is turned on Verify that the box contains the following items N 1 SG HALFPAR24 N 2 Bracket N 1 Power cord N 1 User Manual FRONT VIEW 1 Bracket knob 2 Lens 3 Bracket REAR VIEW 1 Power IN OUT 2 Display keypad...

Страница 16: ...d on the floor resting on the rubber feet on the wall ceiling or on a truss WARNING IT S REQUIRED the mounting of the safety rope PLH200 sold separately in the case where the product is hung on a wall ceiling or on a truss Except when the device is placed in the floor the safety cable is always required All manuals and user guides at all guides com a l l g u i d e s c o m ...

Страница 17: ...ta label 4 3 CONNECTION TO THE DMX CHAIN Use a cable conforming to specifications EIA RS 485 pole twisted shielded 120Ohm characteristic impedance and low capacity PROEL DMXD DMXD1 Do not use microphone cable or other cable with different characteristics than those specified Terminations must be made with male female XLR 3 pin connectors You must enter on the last device a terminal plug with a 120...

Страница 18: ...tion of Blue SP 01 SP 99 Manual regulation of strobe SLAV SLA Slave mode 5 2 MASTER SLAVE MODE In this mode more units can be linked together as a single chain and work in a synchronized way Use a DMX cable to link together all the units from the connector DMX OUT to DMX IN Define the first unit of the chain as MASTER all other units must be set in SLAVE mode SLAU SLA Operate the Master unit in Au...

Страница 19: ...5 Non usato 000 255 Strobe from min to max for ch 2 3 and 4 7 channels mode Channel Value Function 1 000 255 Master Dimmer 2 000 255 Red 3 000 255 Green 4 000 255 Blue 5 000 024 Not used 025 049 Run all programs 050 074 Run program 2 075 099 Run program 3 100 124 Run program 4 125 149 Run program 5 150 174 Run program 6 175 199 Run program 7 200 255 Sound mode 6 000 255 Speed programs ch 5 7 000 2...

Страница 20: ... lenses like any other damaged part must be replaced with original spare parts 7 TECHNICAL SPECIFICATIONS Power Supply 100 240V 50 60HZ LED 24x3W RGB 3 in 1 Beam Angle 25 Power conumption 82W Operation Mode Auto Sound active Master slave DMX512 Electronic Dimming 0 100 DMX 3 6 7 Channels Digital display for address and function setting Power input and power output for link Dimensions L x H x D mm ...