1-Free Sagemcom - Modification with the authorization of the management concerned
– This docu-
ment and the information it contains is the property of Sagemcom
3000499643-R11-000-01
Page 23
UM User Manual (EN) rev. 3.2
Table 4: Summary of supported events
ID
Event name
Level
Event description
Parameters
FLA
G
10
FLAG_ACTIVITY
INFO
Activity detected or finished
in the optical flag
[1 byte]
1: FLAG activity
detected
0: FLAG activity
finished
11
FLAG_ERROR_CRC
WARN
Incorrect CRC on the last
frame
NA
R
A
D
IO
20
Radio attachement:
START
INFO
Join request sequence
started
NA
21
Radio attachement:
SUCCESS
INFO
Join request accepted
[4 bytes] device
address
22
Radio send
DEBUG
Radio frame sent
[1 byte] FPort of
the rx frame
[1 byte] Size of
payload
[1 byte] Data
rate
23
Radio receive
DEBUG
Radio frame received
[1 byte] FPort of
the rx frame
[1 byte] Size of
payload
[1 byte] Data
rate
25
Radio attachment:
FAILURE
I
NFO
Supervision frame sent
NA
C
MD
40
CMD_ACCESS_LVL
INFO
User with particular access
level started a session
[1 byte] New ac-
cess level
[3 bytes] User
Identifier
ME
T
E
R
50
METER_STATE
INFO
Meter switched from state A
to state B
[1 byte] State A
[1 byte] State B
51
METER_ALARM
CRIT
Meter alarms mask changed
[1 word] Alarms
mask
52
DEVICE_REBOOT
INFO
Device rebooted
NA
53
DISPLAY_STATE
INFO
Display enabled or disabled
[1 byte]
1: Screen is en-
abled
0: Screen is dis-
abled
60
MONTHLY
INFO
Monthy event to keep track
of time
NA
61
PARAM_RESET
WARN
Internal parameters reset
NA