15
SH6- HEATER CONTROLLER SERIES
T1
-
L1,L2,L3
The 3 phase supply to the PC550/7 control
card. Care must be taken since the rotation
order of the phases is critical. (Internal
connection).
T2
-
CT1,CT2,CT3
CT connections used for current control.
(OPTIONAL).
GND
Tacho Negative – (Ground)
T3
-
F/B
Tacho Feedback Po
MIN SPD
Potentiometer Negative, 0 volt
VOLT REF
Potentiometer Wiper, control Voltage
+22V
Positive Card voltage
T4
-
+12V
Potentiometer Positive, 12 Volt
HOLD
Starting Latch
STRT
Start input
OT1
Over Temperature 1
T5
-
OT2
Over Temperature 2
RL2 COM
Relay 2 Common
RL2 N/O
Relay 2 Normally Open Contact
T6
-
RL2 N/C
Relay 2 Normally Closed Contact
RL3 COM
Relay 3 Common
RL3 N/C
Relay 3 Normally Closed Contact
T7
-
RL3 N/O
Relay 3 Normally Open Contact
mA+
mA-
Current analogue reference input Po
Analogue current reference input Negative–
3.2
FUSE RATINGS