USER MANUAL
EvaluationTools
STIM300 STIM377H Evaluation Kit
DOK453 rev.2
Page 23 of 29
Service mode is entered by clicking on the Service mode tab next to the Normal mode tab after the gyro module has
been powered up. Service mode usage, functionalities and descriptions are listed in Table 5. Exit from Service mode
to Normal mode by selecting one of the other panel tabs (Normal, Logging, Service or Parameter panel tab).
Note: Changes made for the gyro module in Service mode are only stored permanently in flash memory when the
save command (‘s’) subsequently is sent to the gyro module.
Panel content
Functionality and description
Available commands window
Shows a list of available commands. See product datasheet for details
Complete command window
Contains the complete command to be sent. The command is auto-completed by
the software during usage of the listings in the Available commands window. Left
click inside the Complete command window brings up a list of previously sent
commands. Right click enables manual command entry
Send command button
Sends command to the gyro module
Active device indicator
Indicates active gyro module. Corresponding COM port is specified in the active
parameter file
Command response window
Shows the responses to commands from the gyro module. See product datasheet
for details
Erase button
Clears the content of the command response window
Save button
Saves the content of the command response window to a text file with a date and
time tag
Table 5: Service mode panel descriptions
7.5
Utility mode panel
Utility mode is used for configuration and communication with the STIM300/STIM377H through a machine-to-machine
interface.
Utility mode is entered by clicking on the Utility mode tab after the IMU has been powered up. Utility mode usage,
functionalities and descriptions are listed in
. Exit from Utility mode by selecting any available panel tab.
Note: Changes made to the IMU in Utility mode are permanently only when the settings are saved to flash memory.
Panel content
Functionality and description
Available commands window
Shows a list of available commands. See product datasheet for details
Complete command window
Contains the complete command to be sent. The command is auto-completed by
the software during usage of the listings in the Available commands window. Left
click inside the Complete command window brings up a list of previously sent
commands. Right click enables manual command entry
Send command button
Sends command to the IMU
Command response window
Shows the responses to commands from the IMU. See product datasheet for
details
Erase button
Clears the content of the command response window
Save button
Saves the content of the command response window to a text file with a date and
time tag
Table 6: Utility mode panel descriptions
7.6
Measure panel
Panel content
Functionality and description
Measure button
Starts a measurement series
Samples box
Defines the number of samples to be collected (max 50 MS)
Save to file button
Saves data from a completed measurement series to a result file. The file path
defined in the active parameter file is proposed
X-, Y- and Z-axis check boxes Selects which axis data to present in the graph area (up to 3 axes can be plotted
simultaneously)