MorphoAccess® VP Series - User Guide
Section 10:
MorphoAccess® Terminal Customization
SSE-0000082427-01
M
ORPHO DOCUMENT
.
R
EPRODUCTION AND
D
ISCLOSURE
P
ROHIBITED
88
January 2011
Please refer to the
MorphoAccess® VP Series Installation Guide
for more information
about the anti-tamper and the anti-pulling switches.
Configuration keys
The action(s) to be performed by the MorphoAccess® terminal is defined by a unique
dedicated configuration key.
Tamper alarm level
app/tamper alarm/level = 0
Disabled: Anti-pulling and anti-tamper switches are
ignored (default)
app/tamper alarm/level = 1
Silent message only: an alarm message is sent to a
distant system.
app/tamper alarm/level = 2
Silent message and local alarm signal: in addition
to previous level (1), the terminal buzzer emits an
audible and visible alarm signal
The alarm message is sent through the same channel as the “access control result”
message. Then, if there is no channel defined for the result message, the alarm
message is not sent. Please refer to
Sending the access control result to a distant system
section.
In addition if the alarm message is to be sent through the serial port using Wiegand or
DataClock protocol, it is mandatory to:
•
Enable the sending of error messages.
•
Change the error code of the message is default value cannot be used
Allows the sending of error messages (DataClock/Wiegand protocol)
app/failure ID/enabled=1
Enables error message
Anti-pulling or anti-tamper alarm message identifier (Wiegand or DataClock)
app/failure ID/alarm ID
65535 (0 – 65535)