Saflok InSync L Скачать руководство пользователя страница 2

InSync

®

  L Installation Instructions 

 

Pg. 2 of 2 

©  SAFLOK™ 

 

WL 4/23/2008 

5.  Before installing the inner trim, rotate the lever to insure that the tailpiece cam (see Fig.1, Detail “B”) 

is in the correct orientation. While placing the inner trim in position, feed the cables through the 
appropriate hole in the inner chassis and attach the trim with two 1/4-20 x 2-5/8 flat head Phillips 
machine screws and one 1/4-20 x 2 pan head Phillips machine screws. 

 
6.  Plug the wire harnesses into the appropriate inner trim wires (battery and optional lever switch). 

Secure the wires with the wire tie to either loop on the chassis.  

 
7.  Install the four AA alkaline batteries.   
 

Important:

 As the last battery is installed, watch for the LED on the outside of the lock to flash 

(reset). 

 
8.  With the thumb turn in the vertical position place the inner cover on the inner assembly. Secure the 

cover with the matching tamper-proof screws (supplied). A TR20 Torx bit and construction keys are 
included in the Start Up Kit. 

 
9. 

Important: 

Before closing the door, check lock function using the construction key, thumb turn, and 

inner lever and outer levers.

 

 
     
 
 
 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Secure the wires with the 

wire tie to either loop on the 

chassis

Insure thumb turn

is vertical

Fig. 2 

 
Secure the wires with the wire tie 
to either loop on the chassis. 

 
Insure that the thumb 
turn is vertical. 

Questions? 

Call Customer Service at 800.999.6213 and select option 3. 
For online assistance, visit support.saflok.com. 