![Safire SD6118I-2PTVI Скачать руководство пользователя страница 37](http://html1.mh-extra.com/html/safire/sd6118i-2ptvi/sd6118i-2ptvi_user-manual_3399663037.webp)
User Manual of HD-TVI Speed Dome
31
(1)
Move the cursor to
ALARM NO.
and click the
IRIS+
to enter edit mode.
(2)
Click the up and down direction buttons to select the number of the alarm which is to be
configured.
(3)
Click
IRIS+
again to confirm and exit edit mode of this column.
You can configure up to 2 alarm inputs.
3.
Move the cursor to
ALARM SETTING
and click the
IRIS+
to enter the setting alarm submenu.
4.
Configure the alarm input.
Steps:
(1)
Move the cursor to
ALARM INPUT
and click the
IRIS+
to enter edit mode.
(2)
Click the up and down direction buttons to set the input status. You can configure it as
OPEN
(Normally open),
CLOSE
(Normally closed) or
OFF
(disable the alarm input).
(3)
Click
IRIS+
again to confirm.
If you set the status as
OPEN
, alarm will be triggered by high electricity level; if you set
the status as
CLOSE
, alarm will be triggered by low electricity level; if you set the status as
OFF
,
it will be triggered when this input channel is shut off.
5.
Configure the alarm linkage action.
You can specify the linked action when an alarm occurs.
(1)
Move the cursor to
LINKAGE
and click the
IRIS+
to enter edit mode.
(2)
Click the up and down direction buttons to choose the desired linkage action. You can set
the alarm action as preset from 1 to 8, pattern from 1 to 5, patrol from 1 to 10, panning
scan, tilting scan, panoramic scan, day mode, night mode or none. You can also set the
alarm output for the alarm. Please refer to
Section 3.5.3
for
details.
6.
Configure alarm priority.
Enter the
PRIORITY
menu and set the alarm priority as
HIGH
,
MIDUEM
or
LOW
.
If multiple alarms with different priorities are triggered at the same time, the dome only
responds to the alarm with the highest priority. If multiple alarms with the same priority are
triggered at the same time, then the dome will respond to each alarm according to the defined
alarm sequence.
3.5.2
Configuring Alarm Parameters
Purpose:
You can set the alarm related parameters following below instructions, including linkage action
interval, alarm duration and dome activity resumption.
Steps:
1.
Enter the alarm parameter configuration menu:
MAIN MENUS > DOME SETTINGS > ALARM INPUT
2.
Configure the interval of the alarm sequence.
When more than one alarm of the same priority occurs at the same time, the speed dome will
respond to one alarm first and then respond to the next one after the user-defined interval. You
can set the on
SEQUENCE
submenu
from 1 to 200 seconds.
Содержание SD6118I-2PTVI
Страница 1: ...HD TVI Speed Dome User Manual UD02205N...