SafeWaze LATITUDE HD SRL-P Скачать руководство пользователя страница 3

Copyright Safewaze 2023

Page 3

User must read, understand, and follow all safety and usage information contained within this manual prior to use of this equipment.  Failure to follow 

all safety and usage information can result in serious injury or death.

 

WARNINGS AND IMPORTANT PRECAUTIONS

Intended Use:

The equipment covered in this manual is intended for use as part of a complete Personal Fall Arrest System (PFAS). 

Use of this equipment for any other purpose, such as material handling, sports activities, or other action not described in these User Instructions is 

not approved by Safewaze.  Use of this equipment in a manner outside the scope of those covered within this Manual can result in serious injury or 

death.  

The equipment covered in this manual is only to be used by trained personnel in workplace applications. 

WARNING

IMPORTANT

Safewaze Self Retracting Lifelines (SRLs) are part of a complete PFAS.  Every user must be trained in the inspection, installation, operation, and proper 

usage of their complete PFAS.  Unapproved or inappropriate use of Safewaze SRLs could result in serious injury or death. Refer to these instructions for 

the proper selection, installation, maintenance, and service of this equipment.  For questions regarding use of this equipment beyond the scope of this 

manual, contact Safewaze.  

• 

 

The warnings below are designed to reduce the risks associated with the use of Safewaze SRLs:

• 

User must inspect the SRL prior to each use which includes a check for proper locking and retraction.

• 

If the inspection reveals an unsafe or defective condition, the SRL must be removed from service and destroyed or repaired as specified 

in this manual.

• 

If a Safewaze SRL is exposed to fall arrest or impact forces, it must be immediately removed from service and tagged “Unusable”.

• 

Never allow slack to form in the SRL lifeline constituent.  Never tie or knot the lifeline.

• 

Utilize extra caution to keep the lifeline free from any obstructions including but not limited to; surrounding objects, tools, equipment, 

moving machinery, co-workers, yourself, or possible impact from overhead objects that could come into contact with the lifeline or worker.

• 

Avoid making sudden or quick movements as this could cause the SRL to inadvertently lock. 

• 

Do not use a Safewaze SRL in an environment where the fall path is obstructed.  Use of a Safewaze SRL on slowly shifting or unstable  

material such as grain or sand, or within cramped or confined spaces, may not allow the worker to reach adequate speed for the SRL 

lock up, resulting in possible engulfment.

• 

Work directly under the anchor point as much as possible to reduce risk of striking an object due to swing fall. 

• 

Unused leg(s) of a harness mounted SRL must be attached to the parking component on the front of the harness. 

• 

If the PFAS is made up of components from different manufacturers, ensure that all components of the PFAS are compatible with each  

other and meet all applicable standards, regulations, or requirements.  A Competent or Qualified Person should always review and 

approve the PFAS system prior to worker use.

• 

Avoid lifeline contact with sharp or abrasive surfaces.

• 

DO NOT use combinations of components or subsystems, or both, that may affect or interfere with the safe function of each other

• 

DO NOT alter equipment

• 

DO NOT misuse equipment

• 

User must have a written Rescue Plan and means at hand to implement it when using this equipment.  All employees should be trained 

and knowledgeable in the Rescue Plan and Rescue Operations.

• 

Avoid exposure of this equipment to chemicals, high heat, severe cold or other harsh environments which may produce a harmful effect.  

If in doubt about serviceability of this equipment, contact Safewaze.   

• 

Fall protection equipment that fails inspection must be removed from service and tagged “Unusable”.  The equipment should then be 

        returned to Safewaze for repair / service (if applicable) or destroyed.  For questions regarding service / repair of components, 

        contact Safewaze. 

• 

Never exceed the maximum allowable weight capacity of your fall protection equipment. 

• 

Never exceed the maximum free fall distance of your fall protection equipment.

• 

Only Safewaze, or entities authorized in writing by Safewaze, may make repairs to Safewaze fall protection equipment.

• 

User(s) of Safewaze fall protection equipment must ensure that their health and physical condition allows them to withstand all forces 

and  potential risks associated with working at heights.  ANSI limits the weight capacity of fall protection equipment to a maximum of  

310 lbs.  Some equipment covered in this manual may indicate a weight capacity in excess of 310 lbs.  Although some equipment may 

be rated to a higher capacity, it should be noted that heavier users are at an increased risk of serious injury or death. This being due to  

increased forces on the body during a fall, and the risk for accelerated onset of suspension trauma. 

• 

Use of a body belt is NOT authorized for fall arrest applications.  Use only a Full Body Harness (FBH).

• 

Always wear required personal protective equipment when installing, using, or inspecting this equipment.

• 

If conducting training operations with this equipment, ensure that a secondary fall protection system is installed and utilized in a manner  

that does not expose the trainee to unintended fall hazards.

• 

Immediately seek medical attention in the event a worker suffers a fall arrest incident. 

• 

Certain subsystems may interfere with the proper operation of the equipment in this manual.  Use only compatible connections.  Contact  

Safewaze for questions regarding compatibility of equipment or components not covered in this manual.

• 

Avoid objects, equipment, or surfaces that could harm the user or equipment. 

• 

User must ensure that there is adequate fall clearance when working at height.

• 

Extra precautions must be taken if working in the vicinity of moving machinery, electrical hazards, chemical hazards, sharp edges, 

        explosive or toxic gases, extreme temperatures, or below overhead equipment or materials that could impact the user and his/her fall 

        protection equipment.

• 

If work is conducted in a high heat environment, ensure that Arc Flash or other suitable fall protection equipment is utilized.   

• 

 

Users should enact the precautionary measures listed below to reduce the inherent risks of working at height:

These instructions shall be provided to the user.  User must read, understand, and follow all safety and usage information contained within 

this manual prior to use of this equipment.  Failure to follow these instructions or improper use can result in serious injury or death.

 

Содержание LATITUDE HD SRL-P

Страница 1: ...anufacturer s Instructions as required by ANSI Z359 14 2021 and should be used as part of an employee training program as required by OSHA Copyright Safewaze 2023 SRL P Instruction Manual 220 00081 AN...

Страница 2: ...RREST DISTANCE MIN REQ FALL CLEARANCE 8 10 11 0 SWING FALLS 10 11 12 0 FALL PROTECTION AND RESCUE PLAN 12 13 0 NORMAL OPERATIONS 12 14 0 COMPATIBILITY OF COMPONENTS 12 15 0 COMPATIBILITY OF CONNECTORS...

Страница 3: ...ems or both that may affect or interfere with the safe function of each other DO NOT alter equipment DO NOT misuse equipment User must have a written Rescue Plan and means at hand to implement it when...

Страница 4: ...inum 4 4 X X X FS FSP1409 W 1 S 9 UHMPE webbing 1X 05 Aluminum 3 6 X X FS FSP1409 W RBH 1 S 9 UHMPE webbing 1X 05 Aluminum 4 6 X X 020 5270 1 S 9 UHMPE webbing 1X 05 Aluminum 3 1 X X FS FSP1409 W DL 1...

Страница 5: ...and 2 Class 1 Self retracting devices which shall be used only on overhead anchorages and shall be subjected to a maximum free fall of 2 feet 0 6 m or less in practical application Class 2 Self retra...

Страница 6: ...Figure 2 Illustrates a Fall Clearance Calculation Fall Clearance FC is the total combined values of Free Fall FF Deceleration Distance DD and a Safety Factor SF Safety Factor calculations may differ...

Страница 7: ...oyer to perform duties at a location where such person will be exposed to a fall hazard 2 Rescuer Person or persons other than the rescue subject acting to perform an assisted rescue by operation of a...

Страница 8: ...Latitude HD SRL P series Fall Clearances indicated in Table 7 are calculated using the greatest Actual Arrest Distance out of the four tests performed on each model Table 6 indicates the specific arr...

Страница 9: ...the anchorage connector to arrest a fall before the user strikes the ground or an obstruction Figure 2 illustrates a typical Fall Clearance calculation based on the ANSI Z359 14 2021 prescribed Maximu...

Страница 10: ...CA TOR A FALL ARREST 4 ft 3 ft 2 ft 1 ft 0 ft 1 ft 2 ft 3 ft ANSI Z359 14 ANSI A10 32 OSHA 1910 66 OSHA 1926 502 0 2 0 0 5 3 0 ft FREE FALL ANCHORAGE DISTANCE ABOVE OR BELOW D RING 0 ft 0 ft 0 ft 0 ft...

Страница 11: ...d above the user s Dorsal D ring The X Axis represents lateral movement of the worker in relation to the SRL Example Latitude HD SRL Anchored Overhead This example represents the user anchored 5 Overh...

Страница 12: ...ECTORS HAVE ADDITIONAL REQUIREMENTS CONTACT SAFEWAZE WITH QUESTIONS Connectors are compatible with connecting elements when they have been designed to work together in such a way that their sizes and...

Страница 13: ...with the effects of a fall must be removed from service immediately Equipment must then be serviced See Section 18 if applicable or disposed of See Section 19 16 0 USE 16 1 OPERATION 16 2 AFTER A FAL...

Страница 14: ...ivels should be hanging on the curved portion of bracket 4 Slide the bar behind both loops of webbing at dorsal D ring Swing the bracket closed unti it locks into place 5 Check the locking function of...

Страница 15: ...ing back into the housing DO NOT USE HEAT to dry web lifeline IMPORTANT If the lifeline comes in contact with acids or other caustic chemicals remove the SRL from service and wash with water and a mil...

Страница 16: ...s equipment Standards ANSI Z359 14 2021 OSHA 1910 140 and 1910 66 MODEL FS FSP1411 W DESCRIPTION Latitude HD 11 Single Web SRL Carabiner Snap Hook SERIAL XXXXXXX MFG DATE XX XXXX MUST FOLLOW ALL MANUF...

Страница 17: ...OSHA 1926 502 020053 ANSI Z359 14 ANSI A10 32 OSHA 1910 66 OSHA 1926 502 020053 FIGURE 13 INSPECTION DIAGRAMS LATITUDE HD CABLE UNITS FAIL PASS 470 00041 Swivel Fall Indicating Snap Hook Swivel Fall I...

Страница 18: ...ok Body Rivets Corrosion Pitting Nicks CONNECTORS PASS FAIL NOTE Termination Stitch Splice or Swage Cuts Fraying Broken Stitching Excessive Wear Cable Separating Bird Caging Entire Length Retracts Smo...

Страница 19: ...Copyright Safewaze 2023 Page 19 Date Inspection Items Noted Corrective Action Initials INSPECTION LOG...

Страница 20: ...Copyright Safewaze 2023 Page 20 Safewaze 225 Wilshire Ave SW Concord NC 28025 PHONE 1 800 230 0319 FAX 1 704 262 9051 WEB safewaze com EMAIL info safewaze com...

Отзывы: