Safety Vision SV-IR-THRM Скачать руководство пользователя страница 9

sv-ir-thrm user guide

7

5. 

Slide the thermometer with attached bracket into the bracket arm and secure it 
in place with the included two Phillips  head screws and washers.

Содержание SV-IR-THRM

Страница 1: ...sv ir thrm USER GUIDE PATENT PENDING...

Страница 2: ...ited to the implied warranties of merchantability and fitness for a particular purpose Safety Vision shall not be liable for errors contained herein or for incidental or consequential damages in conne...

Страница 3: ...9 SV IR THRM BRKT 11 Components 14 Operating the SV IR THRM Start up 15 Shutdown 15 Display Version Number 15 Check the Device ID 15 Settings Volume 17 Temperature Display Units 17 Not Used 17 Minimum...

Страница 4: ...sv ir thrm user guide 2 ID Number 19 Restore Factory Settings 20 Thermo Detection Notes 20 Appendix A Specifications 21 Appendix B Dimensions 21 FCC Compliance Statement 22...

Страница 5: ...walk through metal detectors doors intelligent access control systems and more Features No contact temperature measurement The detector measures forehead or hand temperatures and is accurate up to 3...

Страница 6: ...nes up with a specific hole pattern on the back of the thermometer The types of mounting brackets are 1 Horizontally rotating included 2 1 1 4 U bracket included 3 SV LCD RM1 0 4 diamond ball base sho...

Страница 7: ...zontally Rotating Mounting Bracket The horizontally rotating mounting bracket uses the holes indicated below on the back of the thermometer shroud 1 Remove the two 2 Phillps head screws that secure th...

Страница 8: ...t to the center two holes shown on page 3 3 Using the two Phillips head screws removed in step 1 to secure the bracket to the shroud 4 Using the included three self tapping screws and wall anchors if...

Страница 9: ...sv ir thrm user guide 7 5 Slide the thermometer with attached bracket into the bracket arm and secure it in place with the included two Phillips head screws and washers...

Страница 10: ...1 4 U bracket uses any two holes shown below on the back of the thermometer shroud to mount the thermometer to a rail or pole Using two of the included Phillips head screws secure the U bracket aroun...

Страница 11: ...ide 9 SV LCD RM1 0 4 NOTE When installing the SV LCD RM1 0 4 it s necessary to use the included hardware kit SV IR THRM SCRW The SV LCD RM1 0 4 mount uses the indicated holes below on the back of the...

Страница 12: ...ometer 2 Line up the holes of the diamond ball base to the center two holes and use the 2 Phillips head screws included in SV IR THRM SCRW to securely fasten the base to the thermometer 3 Using the fo...

Страница 13: ...SV IR THRM BRKT The SV IR THRM BRKT bracket uses the four outermost shown below on the back of the thermometer shroud to mount the thermometer to a rail or pole 1 Remove the retaining screw and slide...

Страница 14: ...most holes on the thermometer 3 Using the four Phillips head screws wrapped in packing foam included in the box securely fasten the bracket to the thermometer 4 Using the included four self tapping sc...

Страница 15: ...rm user guide 13 5 Slide the thermometer with mounting bracket onto the mounting plate and replace the retaining screw Loosen the wing nut on either side of the bracket to adjust the angle of the ther...

Страница 16: ...pace to the right 4 Power Button disabled When connected to a power source the thermometer is always on 5 Normal LED Indicator LED activates when detected temperature is within the 95 F 100 4 F 35 C 3...

Страница 17: ...system turn off power source or unplug power cable Display Version Number Press the Select button twice and the version number will display then press the Select button to return to the main interfac...

Страница 18: ...n to the main interface or continue to press Select after each setting to continue to the next setting Settings Use the following steps to access the thermometer s settings 1 Press the Enter button CC...

Страница 19: ...ge values Default 6 Range 0 8 Note 0 mute 8 loudest Default 1 0 Range 1 0 7 0 1 2 Volume Not Used Default 1 Range 0 1 Note 0 Celcius 1 Fahrenheit Default 2 Range 2 3 Note 2 alert sounds when temperatu...

Страница 20: ...ture detection in mm Default 5 Range 5 6 5 6 Maximum Detection Distance Ambient Body Default 050 Range 000 200 Note Minimum distance for temperature detection in mm Default 1 0 Range 1 0 3 0 Note Leng...

Страница 21: ...hen use the Adjust and Select buttons to input the password 1111 4 Press the Enter button twice 0000 then FFFF will appear on the display 5 From here the ID number can be modi ed using the Select and...

Страница 22: ...actory Settings Use the following steps to restore the IR thermometer back to factory settings 1 Press the Enter button CCCC will appear on the display 2 Press the Select button once 1234 will show on...

Страница 23: ...mm Power consumption Less than 8W External power supply for fixed applications only 120V AC converter Working voltage 12V Working temperature 14 F 104 F 10 C 40 C Operating humidity 95 non condensing...

Страница 24: ...operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful int...

Страница 25: ...orporate Headquarters 6100 W Sam Houston Pkwy N Houston TX 77041 5113 www safetyvision com Main 713 896 6600 Toll Free 800 880 8855 Fax 713 896 6640 Copyright 2020 Safety Vision LLC All Rights Reserve...

Отзывы: