I
NSTALLATION
I
NSTRUCTIONS
Note: STI recommends setting up unit and testing settings prior to mounting.
1. Make sure key switch is in the OFF
position.
2. Remove tamper screw on side of
unit and remove housing cover.
Save this tool for future servicing
and battery change (Figure 2).
3. Set switches, on circuit board, to
desired alarm settings (figure 1).
4. Test settings by connecting battery
or external power source. If using
external power source a Class II UL
Listed transformer is required. If
power is present at terminal block
(figure 1) 9V battery is in no-load
on standby power consumption.
19039 SCREW
6 x 1 1/4 in.
(2) PROVIDED
19018 ANCHOR
(2) PROVIDED
BOTTOM SURFACE AS SHOWN
WIRES THROUGH NOTCH ON
AND ROUTE REED SWITCH
REMOVE FRONT COVER
VIEW SHOWING MAGNET INSTALLATION
MAGNET
MAXIMUM GAP 3/4 in. (19mm)
3/8 in. (9.5mm) ON METAL DOOR
AND FRAME
SPACERS (USE AS NECESSARY)
NOTE: 2 SPACERS UNDER BOTH
MAGNET AND REED SWITCH
MUST BE USED ON STEEL DOORS
FIGURE 2
FIGURE 3
A
LARM
F
EATURE
D
ESCRIPTION
•
Volume Switch JP2
- Sets alarm volume to high 105 dB or low 95 dB.
•
Duration Switch JP3 and JP4
- Amount of time alarm sounds after trip. Arming resets at end
of duration if door is closed. Alarm will not reset if in continuous mode; alarm sounds until
battery is drained. Annunciator Mode is a series of 10 short beeps or until door is closed.
•
Trip Delay Switch JP5
- If you wish to
ENTER
an alarmed door without sounding the horn
immediately, the trip delay will allow 15 seconds for you to enter and de-activate the alarm
with the key switch before the alarm will sound.
•
Arming Switch JP7
- This mode is useful when an
AUTHORIZED EXIT
is required through
alarmed door. In “ON” position immediate arming will set the alarm ready to function as soon
as door is opened. In “OFF” position delay arming will allow 15 seconds for you to exit through
the door without sending alarm signal.
5. Mount main unit on or next to door using
hardware provided. Reed switch mounting
locations can be moved to one of the four
positions shown in figure 2. If mounted
next to door, route reed switch wire
through knockout in bottom of housing as
shown in figure 3.
6.Mount magnet on door frame (or door if
unit is mounted next to door) using screws
provided. When mounting on metal doors
or door frames, use plastic spacers
provided. Reed switch and magnet must
be within 3/4” when door is closed (3/8”
on metal door and frame). Please refer to
figures 4, 5 and 6 on page 6 for other
mounting options.
7. If installing STI-6402, STI-6403, or STI-6404
continue to page 7 for more instructions
(Figures 7 and 8). STI-6402 mounting
option is shown on page 6.
8. Replace cover by sliding flanges on inside
of cover into slots on base. Then rotate the
cover over unit and snap close. Replace
tamper screw.
FLANGES
SLOTS
TERMINAL STRIP
9 VOLT BATTERY
19011 TAMPERPROOF SCREW
(1) PROVIDED
19016 TAMPER WRENCH
(1) PROVIDED
BASE
COVER
19014 MOUNTING SCREW
(4) PROVIDED
EMERGENCY EXIT ONLY
STOP
STOP
ALARM SOUNDS WHEN DOOR IS OPENED
ON
OFF