Mounting Instructions

1.  Remove the screw knockouts on sensor base for mounting.
2.  Mount at 7.5 ft (ideal height) with provided screws and optional anchors.
3.  Snap unit back onto sensor base.  Unit immediately goes into 3 minute walk test.  To 

reset walk test, remove cover and reattach.

NOTES:

· Clear line of sight from sensor to monitored area, glass will blocks sensor’s view.
· Wall temperature similar to walls/floor of monitored area
· Sensor aimed away from windows and reflected sunlight
· Sensor aimed away from heaters or heater/cooler outlets
· Sensor aimed so intruder path crosses three views.

Specifications

Mounting Hardware: 

#6 screw

Mounting Height:   

7.5 ft. (ideal height)

Replacement battery: 

CR123A 1500mAH

Temperature range: 

-40° to 131°F (-40° to 55°C)

White light immunity: 

25000 lux

RF Immunity 

 

50 V/m 10-1000 MHz; 20 V/m 1-2 GHz

Housing dimensions: 

4.4 x 2.4 x 2” (H x W x D)

Tamper Switch:   

Form A (NC). 50 mA at 30 VDC

Range:

  33 ft./10M in sensor-facing direction

Sensor Optical View Pattern

 (side view, in feet)

0

3.28

6.6

9.9

13

16

20

23

26

30

33

7.5

3.28

Optical Fields-of-View

 Long-range 

Mid-range  Short-range  Look-down

 88° 

30° 

18° 

Sensor Optical View Pattern

 (top view, in feet)

 

26  20  13  6.6   0   6.6  13  20  26

0

6.6

13

20

26

33