Safety Switches HLM Скачать руководство пользователя страница 4

                                 Safety Limit Switches 

 

 

 

 

Mechanical Reliability B10d  

2.5 x 

10

6

 operations at 100mA load

 

EN 954-1 

Up to Category 4 with Safety Relay

 

ISO 13849-1 

Up to PLe depending upon system architecture

 

EN 60261 

U

p to SIL3 depending upon system architecture

 

Safety Data – Annual Usage 

8 cycles per hour / 24 hours per day / 365 days

 

PFHd 

3.44 x 10

-8

 

Proof Test Interval (Life) 

35 years 

MTTFd 

356 years 

Conforming to standards  

EN1088   IEC 947-5-1   UL508  EN50041 

Positive Opening Operation  

NC  Contacts 

Utilization Category  

AC15   A300    240V. 3A. 

Min Current   

5V, 5mA, DC  

Thermal Current (Ith)  

10A  

Rated Impulse Withstand Volt  

2500VAC  

Case Material  

HLM (Die Cast Painted Red)     HLM-SS (Stainless Steel 316) 

Enclosure Protection   

HLM   IP67        HLM-SS   IP67 /  IP69K 

Operating Temperature  

Min. -25°C    Max 80°C 

Mechanical Life Expectancy  

5 x 10

6

 Cycle min.  

Vibration  

IEC 68-2-6, 10-55Hz   0.35mm 

Conductor size 

1.5   sq.mm    

Fixing    

 M5 Bolts 

Quick Connect (QC) 

M23  12 Way  Male 

(connector length 26mm) 

(Pin View from Switch) 

Switch Circuit 

1       3 

11 / 12 

4       6 

21 / 22 

7       8 

33 /34  or  31 / 32 

9      10 

41 / 42  or  43 / 44 

12 

Earth 

Technical Specification: 

 

IDEM SAFETY SWITCHES Ltd., 2 Ormside Close, Hindley Industrial Estate, Hindley Green, Wigan, WN2 4HR   UK.    Tel: +44 (0)1942 257070     Fax.: +44 (0)1942  257076 

IDEM (USA)  4416 Technology Drive, Fremont, CA 94538   Tel:510-445-0751  Fax: 886-431-7064  email:  

[email protected]

  Web: 

www.idemsafety.com

 

Doc: 102534 
Dec. 2013 

 

Safety Classification and Reliability Data: 

Wiring circuits for Explosion Proof  Versions: 

 1 NC   1 NO 

 

2 NC   2 NO 
 

2 NC 
 

Pre-Wired Explosion Proof: 

 

Quick Connect Version: 

 