background image

SABRE INLINE/RELAY Quick Start Guide

   |    8

www.safetrust.com

Set the Activation Distance for your
sensor between touch and 50 ft (15m).
The distance will automatically be set to
30cm, meaning a user needs to be
within 30cm in order to "Auto
Authenticate" to the reader. 

Optional: Activation Distance

The Anti-Passback setting defines the
number of seconds between each
attempt to resend a mobile credential.

Anti-Passback can be used to prevent
users from passing their credential back
for another user to borrow and to stop
users entering an area by simply
following or tailgating another user.

Optional: Anti-passback

When the SABRE information is saved
successfully to Credential Manager and
assigned to the Identity System, the new
description will appear in the Manage
Sensor tab with a unique serial number
assigned.

Step 5: Configuration
complete!

Getting Access:

• To open the door, simply present your
mobile device running the Safetrust
Wallet application to the reader. 
• When the phone is within the
configured activation range, the LED on
the assigned credential for this sensor will
turn yellow.  
• If “Auto Authenticate” is enabled for the
mobile credential, the credential will be
sent to the SABRE whenever the mobile
device is within the activation zone.

Содержание SABRE SA300

Страница 1: ...Install Guide 01 Introduction 02 In the box 03 Specifications 04 Installation 05 Disclaimer SABRE INLINE RELAY www safetrust com Last Updated January 23 2021 ...

Страница 2: ...he Credential Manager for OTA remote management and configuration The SABRE RELAY is an extension of the INLINE device with additional access controller management capabilities The RELAY is ideally suited for parking garages remote buildings and single door offices where no existing cabling or reader infrastructure exists If you order the SABRE INLINE it will come without the relay section of the ...

Страница 3: ... Safetrust Wallet 65mm x 30mm x 12mm Dimensions 5 12 V DC Power Requirements Output Form C relay Wiegand RS 485 OSDP v1 v2 OSDP v2 Secure Channel TTL 5V Wi Fi 2 50 mA BLE 2 15 mA Power Consumption FCC Part 15 Modular Transmitter Certification Canada IC EU EMC CE India ETA WPC RCM RoHS WEEE Certifications Mobile Credential Emulations Most popular 125kHz prox formats from HID Indala AWID GE Casi Far...

Страница 4: ...rust Onboarding Guide before completing the sensor installation www safetrust com Form C Socket B L E E x t A n t e n n a I n p u t M i c r o U S B WiFi Ext Antenna Electrical Installation and Disclaimer Please consult your local jurisdiction to determine what licenses are required to install or modify a low voltage electrical access control and alarm system Instructions in this document do not pr...

Страница 5: ...ons on the reader connector of the Inline Relay and connect the Data 0 and Data 1 outputs from the panel connector to the Wiegand input on the panel For Wiegand translated to RS 485 OSDP connect the wires the same way as above between the reader and the Inline Relay and connect the RS 485 A and RS 485 B outputs from the panel connector to the RS 485 OSDP input on the panel Form C Socket OSDP Wirin...

Страница 6: ... password that you set your Safetrust account up with The Safetrust Wallet App communicates with the sensor via Bluetooth and configures the sensor for an Identity System Step 2 Open the Safetrust Wallet Once the sensor is highlighted click CONFIGURE from the bottom options Step 3 Choose a sensor to manage With the Manage Sensor tab open bring the phone in range of the SABRE and once visible from ...

Страница 7: ...fy the Type of access from the dropdown eg Door Gate etc Assign a short Name and Description using alphanumeric characters Choose an Output for the sensor the default is set to Wiegand Once you have adjusted all the configuration settings scroll to the bottom of the page and click SUBMIT to successfully complete the sensor configuration If the Output is set to OSDP select the Serial Baudrate and s...

Страница 8: ...entering an area by simply following or tailgating another user Optional Anti passback When the SABRE information is saved successfully to Credential Manager and assigned to the Identity System the new description will appear in the Manage Sensor tab with a unique serial number assigned Step 5 Configuration complete Getting Access To open the door simply present your mobile device running the Safe...

Страница 9: ...the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help RF Exposure Mobile RF exposure device there shall be a minimum separation of 20 cm between the device and any users or installers Canada Radio Certification This device complies with Industry Canada license exempt RSS standard s Operatio...

Страница 10: ...one or wearable Safetrust enables employees to move seamlessly through secured doors elevators turnstiles and more Safetrust eliminates the need to replace your existing readers by leveraging your existing infrastructure providing a fast cost effective and convenient upgrade path to touchless virtual credentials Safetrust is headquartered in Fremont California Want to Learn More Contact sales safe...

Отзывы: