background image

Safetrust Inc. | 

safetrust.com

[email protected]

Once the back plate has been fitted and the wiring is complete, the top casing can
be inserted onto the bottom casing like shown above. 

Содержание 8845-000

Страница 1: ...8845 000 Quickstart Guide Last Updated March 2022 ...

Страница 2: ...Contents Safetrust Inc safetrust com sales safetrust com In the box What you ll need Installation Configuration Testing Regulatory Support 01 02 03 04 05 06 07 ...

Страница 3: ...01 Safetrust Inc safetrust com sales safetrust com In the box ...

Страница 4: ... brace the screws inside the wall 6 32 x 375 spanner security screw Option 1 Secures the top and bottom casing together 6 32 x 375 phillips flat head screw Option 2 Secures the top and bottom casing together Sheet metal screw SCR PTP 2X6MM BLUE ZINC CR3 For mounting to wall ...

Страница 5: ...02 Safetrust Inc safetrust com sales safetrust com What you ll need ...

Страница 6: ...ctor Wiegand 4 conductor Twisted Pair Over All Shield and UL approved Belden3107A or equivalent OSDP Linear DC power supply Metal or plastic junction box Drill with various bits for mounting hardware Safetrust Inc safetrust com sales safetrust com ...

Страница 7: ...03 Safetrust Inc safetrust com sales safetrust com Installation ...

Страница 8: ...wall mounted installation begin by pre drilling your holes and insert the nylon screw plugs provided to support the weight of the reader Once secured to the wall you can fix the black plate to the wall using the screws SCR PTP 2X6MM BLUE ZINC CR3 provided ...

Страница 9: ...ect the wires as per the wiring table above Ground Relay In Relay Out Red LED Tamper Green LED Wiegand D0 Data Wiegand D1 Clock F2F 12VDC OSDP RS 485A Wiegand D0 OSDP RS 485B Wiegand D1 Beeper Black Grey Blue Brown Purple Orange Green White Red Aqua Pink Yellow Wire Colors ...

Страница 10: ...Safetrust Inc safetrust com sales safetrust com Once the back plate has been fitted and the wiring is complete the top casing can be inserted onto the bottom casing like shown above ...

Страница 11: ...Safetrust Inc safetrust com sales safetrust com Complete the hardware installation by fixing either the snake eye screw SMF 6 32X5 16 SS or a Phillips screw SMF 6 32X5 16 SS to bottom casing ...

Страница 12: ...04 Safetrust Inc safetrust com sales safetrust com Configuration ...

Страница 13: ...Safetrust Inc safetrust com sales safetrust com Open the Safetrust Wallet APP and select Manage Sensor tab Make sure your system admin has set you up with this role ...

Страница 14: ...Safetrust Inc safetrust com sales safetrust com With the Admin Installer tab open from the App bring the phone in range of the IoT Sensor and once visible from the App highlight and select Configure ...

Страница 15: ...es safetrust com Choose an Identity System Specify the Type of access from the dropdown eg Door Gate etc Assign a short Name and Description using alphanumeric characters Choose an Output for the sensor the default is set to Wiegand ...

Страница 16: ...m sales safetrust com When the IoT Sensor information is saved successfully to Credential Manager and assigned to the Identity System the new description will appear in the Manage Sensor tab with a unique serial number assigned ...

Страница 17: ...05 Safetrust Inc safetrust com sales safetrust com Testing ...

Страница 18: ...st Inc safetrust com sales safetrust com LED Ring Status LED Solid red Indicates idle mode Flashing red Powering up Solid green Success Flashing green Credential is read and access is granted Access with cards ...

Страница 19: ...st Inc safetrust com sales safetrust com LED Ring Status LED Solid red Indicates idle mode Flashing red Powering up Solid Blue Success Flashing Blue Credential is read and access is granted Access with mobile ...

Страница 20: ...06 Safetrust Inc safetrust com sales safetrust com Regulatory Information ...

Страница 21: ...y not cause interference and 2 this device must accept any interference including interference that may cause undesired operation of the device Le présent appareil est conforme aux CNR d Industrie Canada applicables aux appareils radio exempts de licence L exploitation est autorisée aux deux conditions suivantes 1 l appareil ne doit pas produire de brouillage et 2 l utilisateur de l appareil doit ...

Страница 22: ...om sales safetrust com Support Thank you for purchasing the Safetrust IoT Sensor Mini Mullion If for any reason you need assistance with your installation please contact your local Sales representative Sincerely The Safetrust Team ...

Страница 23: ...www safetrust com support ...

Отзывы: