www.safescan.com
18
REMOVE .. - .. PCS
The weight on the scale is too high for the 6165 to determine the exact amount of
coins or banknotes.
SOLUTION:
Remove as many coins or banknotes from the money platform as indicated, until
the 6165 has been able to deternime the amount. Continue counting. Banknotes
should always be placed on the platform in stacks of max. 25 pcs at a time. When
counting of 2 versions of the same denomination is possible:
1st stack of banknotes on the money platform should not exceed 10 pcs
Subsequent stacks of banknotes should not exceed 15 pcs.
REMOVE SOME
Valid for banknote counting only. The weight on the scale is illogical caused by the
weight tolerance of the banknote - the 6165 can not determine the exact amount
of banknotes on the platform.
SOLUTION:
Remove a small amount of banknotes until the 6165 has been able to deternime
the amount. Continue counting. Banknotes should always be placed on the plat-
form in stacks of max. 25 pcs at a time.
When counting of 2 versions of the same denomination is possible:
1st stack of banknotes on the money platform should not exceed 10 pcs
Subsequent stacks of banknotes should not exceed 15 pcs.
BATTERY LOW
Battery power is lower than 5%.
SOLUTION:
Connect the power adapter to recharge the battery. This message can only appear
when the Safescan LB-205 battery is inserted
DEFECT
The loadcell is defect, no weighing / counting possible
SOLUTION:
contact Safescan customer support.